Аннотация

BACKGROUND

The purpose of the present study was to determine cobalt and chromium ion levels in the blood and urine of patients in whom a modern-generation metal-on-metal hip resurfacing device had been implanted.

METHODS

A total of ninety-seven patients with a Conserve Plus metal-on-metal hip resurfacing implant were followed prospectively for two years. Cobalt and chromium levels in erythrocytes, serum, and urine were measured preoperatively as well as three, six, twelve, and twenty-four months postoperatively.

RESULTS

The median serum cobalt and chromium ion levels were 1.04 μg/L (range, 0.31 to 7.42 μg/L) and 2.00 μg/L (range, 0.28 to 10.49 μg/L), respectively, at one year after surgery and 1.08 μg/L (range, 0.44 to 7.13 μg/L) and 1.64 μg/L (range, 0.47 to 10.95 μg/L), respectively, at two years after surgery. The corresponding mean levels (and standard deviations) of serum cobalt and chromium were 1.68 ± 1.66 μg/L and 2.70 ± 2.22 μg/L, respectively, at one year after surgery and 1.79 ± 1.66 μg/L and 2.70 ± 2.37 μg/L, respectively, at two years after surgery.

CONCLUSIONS

These levels compare favorably with other published ion results for metal-on-metal hip resurfacing and replacement implants. No pseudotumors or other adverse soft-tissue reactions were encountered in our study population. Further research is needed to determine the clinical importance of increased cobalt and chromium ion levels in serum and urine following metal-on-metal hip resurfacing.

Для цитирования: Kim Paul R, Beaulé Paul E, Dunbar Michael, Lee Joshua K L, Birkett Nicholas, Turner Michelle C, Yenugadhati Nagarajkumar, Armstrong Vic, Krewski Daniel. Cobalt and chromium levels in blood and urine following hip resurfacing arthroplasty with the Conserve Plus implant.. The Journal of bone and joint surgery. American volume. 2011. DOI: 10.2106/jbjs.j.01721.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.