DOI 10.1007/s11547-012-0853-3

Медицинская библиотека · La Radiologia medica · 2012

Ultrasound-guided transhepatic puncture of the hepatic veins for TIPS placement.

Gazzera C, Fonio P, Gallesio C, Camerano F, Doriguzzi Breatta A, Righi D, Veltri A, Gandini G

СтатьяПеревод в очереди

Аннотация

PURPOSE: This retrospective analysis was carried out to assess the feasibility and results of transjugular intrahepatic portal systemic shunt (TIPS) performed with ultrasound (US)-guided percutaneous puncture of the hepatic veins.

MATERIAL AND

METHODS

Over a period of 3 years, 153 patients were treated with TIPS at our centre. In eight cases, a percutaneous puncture of the middle (n=7) or right (n=1) hepatic vein was required because the hepatic vein ostium was not accessible. Indications for TIPS were bleeding (n=1), Budd-Chiari syndrome (n=1), ascites (n=2), reduced portal flow (n=1) and incomplete portal thrombosis (n=3). A 0.018-in. guidewire was anterogradely introduced into the hepatic vein to the inferior vena cava (IVC) through a 21-gauge needle. In the meantime, a 25-mm snare-loop catheter was introduced through the jugular access to retrieve the guidewire, achieving through-andthrough access. Then, a Rosch-Uchida set was used to place the TIPS with the traditional technique.

RESULTS

Technical success was achieved in all patients. There was one case of stent thrombosis. One patient died of pulmonary oedema. Three patients were eligible for liver transplantation, whereas the others were excluded due to shunt thrombosis (n=1) and previous nonhepatic neoplasms (n=3).

CONCLUSIONS

The percutaneous approach to hepatic veins is rapid and safe and may be useful for avoiding traumatic liver injuries.

Для цитирования: Gazzera C, Fonio P, Gallesio C, Camerano F, Doriguzzi Breatta A, Righi D, Veltri A, Gandini G. Ultrasound-guided transhepatic puncture of the hepatic veins for TIPS placement.. La Radiologia medica. 2012. DOI: 10.1007/s11547-012-0853-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.