MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.talanta.2010.10.052

Медицинская библиотека · Talanta · 2010

Optimization of dispersive liquid-liquid microextraction coupled with inductively coupled plasma-optical emission spectrometry with the aid of experimental design for simultaneous determination of heavy metals in natural waters.

Sereshti Hassan, Khojeh Vahid, Samadi Soheila

СтатьяПеревод в очереди

Аннотация

In this study, dispersive liquid-liquid microextraction (DLLME) combined with inductively coupled plasma optical emission spectrometry (ICP-OES) was developed for simultaneous preconcentration and trace determination of chromium, copper, nickel and zinc in water samples. Sodium diethyldithiocarbamate (Na-DDTC), carbon tetrachloride and methanol were used as chelating agent, extraction solvent and disperser solvent, respectively. The effective parameters of DLLME such as volume of extraction and disperser solvents, pH, concentration of salt and concentration of the chelating agent were studied by a (2(f-1)) fractional factorial design to identify the most important parameters and their interactions. The results showed that concentration of salt and volume of disperser solvent had no effect on the extraction efficiency. In the next step, central composite design was used to obtain optimum levels of effective parameters. The optimal conditions were: volume of extraction solvent, 113 μL; concentration of the chelating agent, 540 mg L(-1); and pH, 6.70. The linear dynamic range for Cu, Ni and Zn was 1-1000 μg L(-1) and for Cr was 1-750 μg L(-1). The correlation coefficient (R(2)) was higher than 0.993. The limits of detection were 0.23-0.55 μg L(-1). The relative standard deviations (RSDs, C=200 μg L(-1), n=7) were in the range of 2.1-3.8%. The method was successfully applied to determination of Cr, Cu, Ni and Zn in the real water samples and satisfactory relative recoveries (90-99%) were achieved.

Для цитирования: Sereshti Hassan, Khojeh Vahid, Samadi Soheila. Optimization of dispersive liquid-liquid microextraction coupled with inductively coupled plasma-optical emission spectrometry with the aid of experimental design for simultaneous determination of heavy metals in natural waters.. Talanta. 2010. DOI: 10.1016/j.talanta.2010.10.052.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.