MedElevator Войти в исследования
← Поиск публикаций

DOI 10.14814/phy2.14510

Медицинская библиотека · Physiological reports · 2020

An intact animal model for the assessment of coronary blood flow regulation "Coronary blood flow regulation".

Boudart Céline, Su Fuhong, Herpain Antoine, Creteur Jacques, Naeije Robert, Brimioulle Serge, Dewachter Laurence, Van Obbergh Luc

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Coronary blood flow adapts to metabolic demand ("metabolic regulation") and remains relatively constant over a range of pressure changes ("autoregulation"). Coronary metabolic regulation and autoregulation are usually studied separately. We developed an intact animal experimental model to explore both regulatory mechanisms of coronary blood flow. Coronary pressure and flow-velocities were measured in four anesthetized and closed-chest pigs using an intracoronary Doppler wire. Metabolic regulation was assessed by coronary flow reserve defined as the ratio between the maximally vasodilated and the basal flow, with hyperemia achieved using intracoronary administration of adenosine (90 µg) or bradykinin (10-6  M) as endothelium-independent and -dependent vasodilators respectively. For both vasodilators, we found a healthy coronary flow reserve ≥ 3.0 at baseline, which was maintained at 2.9 ± 0.2 after a 6-hr period. Autoregulation was assessed by the lower breakpoint of coronary pressure-flow relationships, with gradual decrease in coronary pressure through the inflation of an intracoronary balloon. We found a lower limit of autoregulation between 42 and 55 mmHg, which was stable during a 6-hr period. We conclude that this intact animal model is adequate for the study of pharmacological interventions on the coronary circulation in health and disease, and as such suitable for preclinical drug studies.

Для цитирования: Boudart Céline, Su Fuhong, Herpain Antoine, Creteur Jacques, Naeije Robert, Brimioulle Serge, Dewachter Laurence, Van Obbergh Luc. An intact animal model for the assessment of coronary blood flow regulation "Coronary blood flow regulation".. Physiological reports. 2020. DOI: 10.14814/phy2.14510.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.