MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00216-015-8788-x

Медицинская библиотека · Analytical and bioanalytical chemistry · 2015

Novel chemiluminescent imaging microtiter plates for high-throughput detection of multiple serum biomarkers related to Down's syndrome via soybean peroxidase as label enzyme.

Zhao Fang, Chai Da, Lu Jusheng, Yu Jiachao, Liu Songqin

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Novel chemiluminescent (CL) imaging microtiter plates with high-throughput, low-cost, and simple operation for detection of four biomarkers related to Down's syndrome screening were developed and evaluated. To enhance the sensitivity of CL immunosensing, soybean peroxidase (SBP) was used instead of horseradish peroxide (HRP) as a label enzyme. The microtiter plates were fabricated by simultaneously immobilizing four capture monoclonal antibodies, anti-inhibin-A, anti-unconjugated oestriol (anti-uE3), anti-alpha-fetoprotein (anti-AFP), and beta anti-HCG (anti-β-HCG), on nitrocellulose (NC) membrane to form immunosensing microtiter wells. Under a sandwiched immunoassay, the CL signals on each sensing site of the microtiter plates were collected by a charge-coupled device (CCD), presenting an array-based chemiluminescence imaging method for detection of four target antigens in a well at the same time. The linear response to the analyte concentration ranged from 0.1 to 40 ng/mL for inhibin-A, 0.075 to 40 ng/mL for uE3, 0.2 to 400 ng/mL for AFP, and 0.4 to 220 ng/mL for β-HCG. The proposed microtiter plates possessed high-throughput, good stability, and acceptable accuracy for detection of four antigens in clinical serum samples and demonstrated potential for practical applicability of the proposed method to Down's syndrome screening. Graphical Abstract Schematic evaluation of the microtiter plater for simultaneous detection of the four biomarkers.

Для цитирования: Zhao Fang, Chai Da, Lu Jusheng, Yu Jiachao, Liu Songqin. Novel chemiluminescent imaging microtiter plates for high-throughput detection of multiple serum biomarkers related to Down's syndrome via soybean peroxidase as label enzyme.. Analytical and bioanalytical chemistry. 2015. DOI: 10.1007/s00216-015-8788-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.