MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bioelechem.2023.108452

Медицинская библиотека · Bioelectrochemistry (Amsterdam, Netherlands) · 2023

A convenient fluorescent/electrochemical dual-mode biosensor for accurate detection of Pb2+ based on DNAzyme cycle.

Liu Mingwei, Dong Jie, Suo Zhiguang, Wang Qixuan, Wei Min, He Baoshan, Jin Huali

СтатьяПеревод в очереди

Аннотация

The presence of heavy metals in the ecological environment is a serious threat to human health. Therefore, it is very important to establish a simple and sensitive method for the detection of heavy metals. Currently, most of the methods are single-channel sensing, and these methods are prone to false-positive signals, which reduces the accuracy. In this work, Pb2+-DNAzyme was immobilized on magnetic beads (MBs) using a linkage of biotin and streptavidin and successfully applied to the construction of a fluorescent/electrochemical dual-mode (DM) biosensor. The supernatant after magnetic separation formed a double strand on the electrode, which was combined with methylene blue (MB) for electrochemical detection (EC). At the same time, FAM-d was added to the precipitate, and after magnetic separation, the supernatant was subjected to fluorescent detection (FL). Under optimal conditions, the signal response of the constructed dual-mode biosensor showed a good linear relationship with the concentration of Pb2+. The DNAzyme-based dual-mode biosensor achieved sensitive and selective detection of Pb2+ with good accuracy and reliability, opening a new way for the development of biosensing strategies for the detection of Pb2+. More importantly, the sensor has high sensitivity and accuracy for the detection of Pb2+ in actual sample analysis.

Для цитирования: Liu Mingwei, Dong Jie, Suo Zhiguang, Wang Qixuan, Wei Min, He Baoshan, Jin Huali. A convenient fluorescent/electrochemical dual-mode biosensor for accurate detection of Pb2+ based on DNAzyme cycle.. Bioelectrochemistry (Amsterdam, Netherlands). 2023. DOI: 10.1016/j.bioelechem.2023.108452.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.