MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacc.2003.08.023

Медицинская библиотека · Journal of the American College of Cardiology · 2003

Intracardiac echocardiography-guided transcatheter closure of secundum atrial septal defect: a new efficient device selection method.

Zanchetta Mario, Onorato Eustaquio, Rigatelli Gianluca, Pedon Luigi, Zennaro Marco, Carrozza Antonio, Maiolino Pietro

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

We assessed the use of intracardiac echocardiography (ICE) as the primary means for both selection of the Amplatzer Septal Occluder (ASO) and the guidance of transcatheter closure of secundum atrial septal defects (ASDs).

BACKGROUND

The standard method for transcatheter closure of ASDs requires balloon-sizing maneuver and transesophageal echocardiographic (TEE) monitoring. The role of ICE during transcatheter closure of ASDs has not yet been established.

METHODS

In 91 patients with ASDs, two standardized orthogonal sections were used to obtain ICE-derived measurements of the fossa ovalis and to assess optimal device deployment: the transverse section on the aortic valve plane, and the longitudinal section on the four-chamber plane.

RESULTS

In all patients, ICE planes were identified with excellent resolution, providing proper measurements of the fossa ovalis, from which to derive geometric assumptions for the selection of an appropriately sized device. The ASO waist diameter was chosen on the basis of the r value (r = [square root c(2) + p(2)], where r is the radius of an ideal circle that intersects the elliptical fossa ovalis in its semi-latus rectum, c is the foci half-distance of the fossa ovalis, and p is its semi-latus rectum). During the procedure, the four-chamber plane allowed us to obtain easily interpretable images of all stages of device deployment. Midterm complete occlusion rate was 97.8%. No ICE-related complications occurred.

CONCLUSIONS

The ICE evaluation of ASDs allows quantitative and qualitative information for both proper ASO selection and optimal device placement, thus eliminating the cumbersome balloon-sizing maneuver and the need for general anesthesia during TEE monitoring.

Для цитирования: Zanchetta Mario, Onorato Eustaquio, Rigatelli Gianluca, Pedon Luigi, Zennaro Marco, Carrozza Antonio, Maiolino Pietro. Intracardiac echocardiography-guided transcatheter closure of secundum atrial septal defect: a new efficient device selection method.. Journal of the American College of Cardiology. 2003. DOI: 10.1016/j.jacc.2003.08.023.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.