Sevinc Mustafa, Stamp Susan, Ling Jonathan, Carter Noel, Talbot David, Sheerin Neil S
Аннотация
BACKGROUND: Hypothermic machine perfusion is used to improve renal perfusion and reduce the rate of early and late graft dysfunction. It has been used in our unit since 2001. It has 2 modes of flow: continuous or pulsatile. The aim of this study is to compare the modes of perfusion in terms of perfusion-related parameters, graft survival, and estimated glomerular filtration rate.
METHODS: All donation after cardiac death kidneys between 2002 and 2014 were reviewed. A total of 64 pairs of kidneys were identified of which one kidney underwent pulsatile and the other continuous perfusion. Machine parameters including resistance and perfusion flow index levels at 0, 1, 2, 3, and 4 hours were recorded and glutathione S-transferase was measured in perfusate. Estimated glomerular filtration rate from the first week of transplant until the fifth year and graft survival rates were determined.
RESULTS: Machine parameters were similar at all time points. Estimated glomerular filtration rates and graft survival were the same irrespective of perfusion mode.
CONCLUSION: Pulsatile perfusion may be regarded as more physiological. However, we could not identify difference in outcome following transplant of kidneys from the same donor that had been perfused under pulsatile or continuous conditions.
METHODS: All donation after cardiac death kidneys between 2002 and 2014 were reviewed. A total of 64 pairs of kidneys were identified of which one kidney underwent pulsatile and the other continuous perfusion. Machine parameters including resistance and perfusion flow index levels at 0, 1, 2, 3, and 4 hours were recorded and glutathione S-transferase was measured in perfusate. Estimated glomerular filtration rate from the first week of transplant until the fifth year and graft survival rates were determined.
RESULTS: Machine parameters were similar at all time points. Estimated glomerular filtration rates and graft survival were the same irrespective of perfusion mode.
CONCLUSION: Pulsatile perfusion may be regarded as more physiological. However, we could not identify difference in outcome following transplant of kidneys from the same donor that had been perfused under pulsatile or continuous conditions.