DOI 10.1016/s1760-2734(06)70039-x

Медицинская библиотека · Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology · 2003

Catheter closure of patent ductus arteriosus in dogs: variation in ductal size requires different techniques.

Glaus Tony M, Martin Mike, Boller Manuel, Stafford Johnson Mike, Kutter Annette, Flückiger Mark, Tofeig Magdi

СтатьяПеревод в очереди

Аннотация

BACKGROUND

: Catheter closure of patent ductus arteriosus Botalli (PDA) is increasingly replacing traditional surgical ligation via thoracotomy. A variety of techniques have been described in dogs, although the technique and implant chosen may depend on the minimum ductus diameter.

OBJECTIVES

: To evaluate the feasibility and treatment of choice of catheter closure of large and small PDAs in dogs.

METHODS

: In 16 dogs with a PDA, catheter closure was performed using transarterial embolisation using detachable or free coils, or transvenously using an Amplatzer, duct occluder (ADO).

RESULTS

: In 8 dogs, closure of PDA with a minimum diameter of < 4 mm was achieved using detachable coils; 2 or more coils were required in 3 dogs. In 5 dogs with minimum ductus diameters of > 4 mm, detachable coils were not applicable. In one of these dogs, (incomplete) surgical ligation was performed and later a free coil placed for complete closure. In 2 dogs with moderately large PDA (5 mm), several free coils were implanted. Complete closure was not achieved in either dog and transient haemolysis occurred as a complication. In 2 dogs with a very large PDA (6 mm), implanted free coils embolised to pulmonary arteries and closure was then achieved using an ADO. In 3 dogs with an excessively large PDA (7.5-10 mm) closure was successfully achieved using an ADO with no complications.

CONCLUSIONS

: Coil embolisation is readily feasible for closure of PDA < 4 mm, less feasible for PDA < 5 mm and unlikely to be feasible to close PDA > 5 mm. Detachable coils are safe for PDA < 4 mm, and the ADO is an excellent device for PDA > 5 mm.

Для цитирования: Glaus Tony M, Martin Mike, Boller Manuel, Stafford Johnson Mike, Kutter Annette, Flückiger Mark, Tofeig Magdi. Catheter closure of patent ductus arteriosus in dogs: variation in ductal size requires different techniques.. Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology. 2003. DOI: 10.1016/s1760-2734(06)70039-x.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.