MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1039/d2ra07495h

Медицинская библиотека · RSC advances · 2023

Fast and selective reversed-phase high performance liquid chromatographic separation of UO2 2+ and Th4+ ions using surface modified C18 silica monolithic supports with target specific ionophoric ligands.

Kongasseri Aswanidevi, Madhesan Thirumalai, Mitra Suchashrita, Rao C V S Brahmananda, Nagarajan Sivaraman, Chinaraga Pitchaiah Kancharlapalli, Deivasigamani Prabhakaran, Mohan Akhila Maheswari

СтатьяПеревод в очереди

Аннотация

Reprocessing nuclear-spent fuels is highly demanded for enhanced resource efficacy and removal of the associated radiotoxicity. The present work elucidates the rapid separation of UO2 2+ and Th4+ ions using a reversed-phase high-performance liquid chromatographic (RP-HPLC) technique by dynamically modifying the surface of a C18 silica monolith column with target-specific ionophoric ligands. For the dynamic modification, four analogous aromatic amide ligands, N 1,N 1,N 3,N 3,N 5,N 5-hexa(alkyl)benzene-1,3,5-tricarboxamide (alkyl = butyl, hexyl, octyl, and decyl) as column modifiers were synthesized. The complexation properties and retention profiles of the amide-based column modifiers for the selective and sequential separation of UO2 2+ and Th4+ ions were investigated. In addition, the selective separation of UO2 2+ and Th4+ ions among the competitive ions of similar chemical properties were also studied. The ionophore immobilized C18 silica monolith columns demonstrated a varying degree of retention behavior for UO2 2+ and Th4+ ions (UO2 2+ is retained longer than Th4+ under all analytical conditions), eventually leading to rapid separations within a period of ≤5 min. A 0.1 M solution of 2-hydroxyisobutyric acid (HIBA, 1 mL min-1) served as the mobile phase, and the qualitative and quantitative assessment of the sequentially separated 5f metal ions was achieved through post-column derivatization reaction, using arsenazo(iii) as a post-column reagent (PCR; 1.5 mL min-1) prior to analysis using a UV-vis detector, at 665 nm (λ max). The developed technique was further evaluated by standardizing various analytical parameters, including modifier concentration, mobile phase pH, mobile phase flow rate, etc., to yield the best chromatographic separation. Also, the conceptual role of alkyl chain length (in the modifier) on the retention behavior of the studied metal ions was evaluated for cutting-edge future applications.

Для цитирования: Kongasseri Aswanidevi, Madhesan Thirumalai, Mitra Suchashrita, Rao C V S Brahmananda, Nagarajan Sivaraman, Chinaraga Pitchaiah Kancharlapalli, Deivasigamani Prabhakaran, Mohan Akhila Maheswari. Fast and selective reversed-phase high performance liquid chromatographic separation of UO2 2+ and Th4+ ions using surface modified C18 silica monolithic supports with target specific ionophoric ligands.. RSC advances. 2023. DOI: 10.1039/d2ra07495h.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.