OBJECTIVE

Five years after reporting our initial stent-graft repair of descending thoracic aortic aneurysms experience, we determined the 5- to 10-year results of stent-graft treatment and identified risk factors for adverse late outcomes.

METHODS

Between 1992 and 1997, 103 patients (mean age 69 +/- 12 years) underwent repair using first-generation (custom-fabricated) stent grafts. Sixty-two patients (60%) were unsuitable candidates for conventional open surgical repair ("inoperable"). Follow-up was 100% complete (mean 4.5 +/- 2.5 years; maximum 10 years). Outcome variables included death and treatment failure (endoleak, aortic rupture, reintervention, and/or aortic-related or sudden death).

RESULTS

Overall actuarial survival was 82% +/- 4%, 49% +/- 5%, and 27% +/- 6% at 1, 5, and 8 years. Survival in open surgical candidates was 93% +/- 4% and 78% +/- 6% and at 1 and 5 years compared with 74% +/- 6% and 31% +/- 6% in those deemed inoperable (P <.001). Independent risk factors for death were older age (hazard ratio = 1.1; P =.008), previous stroke (hazard ratio = 2.8; P =.003), and being designated an inoperable candidate (hazard ratio = 1.9; P =.04). Actuarial freedom from aortic reintervention and treatment failure at 8 years was 70% +/- 6% and 39% +/- 8%, respectively. Earlier operative year (hazard ratio = 1.2; P =.07), larger distal landing zone diameter (hazard ratio = 1.1; P =.001), and transposition of the left subclavian artery (hazard ratio = 3.3; P =.008) were determinants of treatment failure.

CONCLUSIONS

Survival after aneurysm repair using crude, first-generation stent grafts was satisfactory in good operative candidates but bleak in the inoperable cohort, raising the question of whether asymptomatic patients should have even been treated. Late aortic complications were detected in many patients, reemphasizing the importance of serial imaging surveillance.

Для цитирования: Demers Philippe, Miller D Craig, Mitchell R Scott, Kee Stephen T, Sze Daniel, Razavi Mahmood K, Dake Michael D. Midterm results of endovascular repair of descending thoracic aortic aneurysms with first-generation stent grafts.. The Journal of thoracic and cardiovascular surgery. 2004. DOI: 10.1016/j.jtcvs.2003.10.047.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.