MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.vascn.2016.04.013

Медицинская библиотека · Journal of pharmacological and toxicological methods · 2016

ECG telemetry in conscious guinea pigs.

Ruppert Sabine, Vormberge Thomas, Igl Bernd-Wolfgang, Hoffmann Michael

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

During preclinical drug development, monitoring of the electrocardiogram (ECG) is an important part of cardiac safety assessment. To detect potential pro-arrhythmic liabilities of a drug candidate and for internal decision-making during early stage drug development an in vivo model in small animals with translatability to human cardiac function is required.

METHODS

Over the last years, modifications/improvements regarding animal housing, ECG electrode placement, and data evaluation have been introduced into an established model for ECG recordings using telemetry in conscious, freely moving guinea pigs. Pharmacological validation using selected reference compounds affecting different mechanisms relevant for cardiac electrophysiology (quinidine, flecainide, atenolol, dl-sotalol, dofetilide, nifedipine, moxifloxacin) was conducted and findings were compared with results obtained in telemetered Beagle dogs.

RESULTS AND

CONCLUSION

Under standardized conditions, reliable ECG data with low variability allowing largely automated evaluation were obtained from the telemetered guinea pig model. The model is sensitive to compounds blocking cardiac sodium channels, hERG K(+) channels and calcium channels, and appears to be even more sensitive to β-blockers as observed in dogs at rest. QT interval correction according to Bazett and Sarma appears to be appropriate methods in conscious guinea pigs. Overall, the telemetered guinea pig is a suitable model for the conduct of early stage preclinical ECG assessment.

Для цитирования: Ruppert Sabine, Vormberge Thomas, Igl Bernd-Wolfgang, Hoffmann Michael. ECG telemetry in conscious guinea pigs.. Journal of pharmacological and toxicological methods. 2016. DOI: 10.1016/j.vascn.2016.04.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.