Transfusion · 2018
Red blood cells treated with the amustaline (S-303) pathogen reduction system: a transfusion study in cardiac surgery.
Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Brixner Veronika, Kiessling Arndt-Holger, Madlener Katharina, Müller Markus M, Leibacher Johannes, Dombos Sarah, Weber Iuliia, Pfeiffer Hans-Ulrich, Geisen Christof, Schmidt Michael, Henschler Reinhard, North Anne, Huang Norman, Mufti Nina, Erickson Anna, Ernst Christine, Rico Salvador, Benjamin Richard J, Corash Laurence M, Seifried Erhard
Аннотация
BACKGROUND: Nucleic acid-targeted pathogen inactivation technology using amustaline (S-303) and glutathione (GSH) was developed to reduce the risk of transfusion-transmitted infectious disease and transfusion-associated graft-versus-host disease with red blood cell (RBC) transfusion.
STUDY DESIGN AND METHODS: A randomized, double-blind, controlled study was performed to assess the in vitro characteristics of amustaline-treated RBCs (test) compared with conventional (control) RBCs and to evaluate safety and efficacy of transfusion during and after cardiac surgery. The primary device efficacy endpoint was the postproduction hemoglobin (Hb) content of RBCs. Exploratory clinical outcomes included renal and hepatic failure, the 6-minute walk test (a surrogate for cardiopulmonary function), adverse events (AEs), and the immune response to amustaline-treated RBCs.
RESULTS: A total of 774 RBC unis were produced. Mean treatment difference in Hb content was -2.27 g/unit (95% confidence interval, -2.61 to -1.92 g/unit), within the prespecified equivalence margins (±5 g/unit) to declare noninferiority. Amustaline-treated RBCs met European guidelines for Hb content, hematocrit, and hemolysis. Fifty-one (25 test and 26 control) patients received study RBCs. There were no significant differences in RBC usage or other clinical outcomes. Observed AEs were within the spectrum expected for patients of similar age undergoing cardiovascular surgery requiring RBCs transfusion. No patients exhibited an immune response specific to amustaline-treated RBCs.
CONCLUSION: Amustaline-treated RBCs demonstrated equivalence to control RBCs for Hb content, have appropriate characteristics for transfusion, and were well tolerated when transfused in support of acute anemia. Renal impairment was characterized as a potential efficacy endpoint for pivotal studies of RBC transfusion in cardiac surgery.
STUDY DESIGN AND METHODS: A randomized, double-blind, controlled study was performed to assess the in vitro characteristics of amustaline-treated RBCs (test) compared with conventional (control) RBCs and to evaluate safety and efficacy of transfusion during and after cardiac surgery. The primary device efficacy endpoint was the postproduction hemoglobin (Hb) content of RBCs. Exploratory clinical outcomes included renal and hepatic failure, the 6-minute walk test (a surrogate for cardiopulmonary function), adverse events (AEs), and the immune response to amustaline-treated RBCs.
RESULTS: A total of 774 RBC unis were produced. Mean treatment difference in Hb content was -2.27 g/unit (95% confidence interval, -2.61 to -1.92 g/unit), within the prespecified equivalence margins (±5 g/unit) to declare noninferiority. Amustaline-treated RBCs met European guidelines for Hb content, hematocrit, and hemolysis. Fifty-one (25 test and 26 control) patients received study RBCs. There were no significant differences in RBC usage or other clinical outcomes. Observed AEs were within the spectrum expected for patients of similar age undergoing cardiovascular surgery requiring RBCs transfusion. No patients exhibited an immune response specific to amustaline-treated RBCs.
CONCLUSION: Amustaline-treated RBCs demonstrated equivalence to control RBCs for Hb content, have appropriate characteristics for transfusion, and were well tolerated when transfused in support of acute anemia. Renal impairment was characterized as a potential efficacy endpoint for pivotal studies of RBC transfusion in cardiac surgery.
Предметные рубрики MeSH
AcridinesAcute Kidney InjuryAgedAged, 80 and overBacteremiaBlood SafetyBlood-Borne PathogensCardiac Surgical ProceduresDouble-Blind MethodErythrocyte TransfusionErythrocytesFemaleGlutathioneGraft vs Host DiseaseHeart Function TestsHemoglobinsHumansLiver FailureMaleNitrogen Mustard CompoundsPostoperative ComplicationsTransfusion ReactionViremiaVirus Inactivation