Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2015

Determination of putrescine, cadaverine, spermidine and spermine in different chemical matrices by high performance liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (HPLC-ESI-ITMS/MS).

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ibarra Alan Alexander González, Wrobel Katarzyna, Escobosa Alma Rosa Corrales, Elguera Julio Cesar Torres, Garay-Sevilla Ma Eugenia, Wrobel Kazimierz

Аннотация

The goal of this work was to establish a simple HPLC-ESI-ITMS/MS procedure, suitable for the determination of four common aliphatic polyamines in two different types of biological matrices. To this end, 1,6-diaminohexane was used as the internal standard (IS) and 4-fluoro-3-nitrobenzenotrifluoride (FNBT) as the derivatizing agent. Formation of fully derivatized compounds was confirmed by high resolution ESI-QTOFMS and MS/MS analysis. Reversed phase chromatographic separation was carried out by gradient elution with 0.1% (v/v) formic acid and methanol. In a positive ESI mode, the following pairs of precursor/quantifier ions were used for multiple reaction monitoring: 467.4/261.0 for PUT, 481.2/461.1 for CAD, 713.7/261.0 for SPD, 959.8/507.2 for SPM and 495.3/475.2 for IS. On-column instrumental detection limits of four polyamines were in the range 0.62-2.14fmol (0.039-0.215ng/ml). Versatility was demonstrated by analyzing plant extracts and human urine; prior to derivatization, all samples were cleaned-up by dichloromethane extraction. The evaluated signal suppression/enhancement was in the range 82.3-115.4% and the percentage recoveries obtained in the method of standard addition were in the range 83.7-114.4%. Statistically significant differences in polyamines concentrations were found in garden cress exposed to Cd(II) versus control seedlings (t-test, p<0.05); results obtained for urine from healthy volunteers and diabetic patients at different clinical conditions suggested possible utility of free polyamines as biomarkers of progressive diabetes.