MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/17434440.2022.2015323

Медицинская библиотека · Expert review of medical devices · 2021

Device profile of the Impella 5.0 and 5.5 system for mechanical circulatory support for patients with cardiogenic shock: overview of its safety and efficacy.

Pahuja Mohit, Hernandez-Montfort Jaime, Whitehead Evan H, Kawabori Masashi, Kapur Navin K

СтатьяОбзорПеревод в очереди

Аннотация

INTRODUCTION

Trans-valvular micro-axial flow pumps such as Impella are increasingly utilized in patients with cardiogenic shock [CS]. A number of different Impella devices are now available providing a wide range of cardiac output. Among these, the Impella 5.0 and recently introduced Impella 5.5 pumps can provides 5.55 L/min of flow, enabling complete left ventricular support with more favorable hemodynamic effects on myocardial oxygen consumption and left ventricular unloading. These devices require placement of a surgical conduit graft for endovascular delivery, but are increasingly being used in patients with CS due to acutely decompensated heart failure [ADHF], acute myocardial infarction [AMI] and after cardiac surgery as a bridge to transplant or durable ventricular assist device surgery or myocardial recovery.

AREAS COVERED: This review focuses on the device profile and use of the Impella 5.0 and 5.5 systems in patients with CS. Specifically; we reviewed the published literature for Impella 5.0 device to summarize data regarding safety and efficacy.

EXPERT OPINION: The Impella 5.0 and 5.5 are trans-valvular micro-axial flow pumps for which the current data suggest excellent safety and efficacy profiles as approaches to provide circulatory support, myocardial unloading, and axillary placement enabling patient mobilization and rehabilitation.

ABBREVIATIONS: pMCS, Percutaneous mechanical circulatory support devices; CS, Cardiogenic shock; ADHF, Acute decompensated heart failure; AMI, Acute myocardial infarction; LVAD, Left ventricular assist deviceI; ABP, Intra-aortic balloon pump; VA-ECLS, Veno-arterial extracorporeal life support.

Для цитирования: Pahuja Mohit, Hernandez-Montfort Jaime, Whitehead Evan H, Kawabori Masashi, Kapur Navin K. Device profile of the Impella 5.0 and 5.5 system for mechanical circulatory support for patients with cardiogenic shock: overview of its safety and efficacy.. Expert review of medical devices. 2021. DOI: 10.1080/17434440.2022.2015323.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало