DOI 10.1213/ane.0000000000002749
Clinical Utility of Intraoperative Motor-Evoked Potential Monitoring to Prevent Postoperative Spinal Cord Injury in Thoracic and Thoracoabdominal Aneurysm Repair: An Audit of the Japanese Association of Spinal Cord Protection in Aortic Surgery Database.
Аннотация
BACKGROUND
Spinal cord ischemic injury is the most devastating sequela of descending and thoracoabdominal aortic surgery. Motor-evoked potentials (MEPs) have been used to intraoperatively assess motor tract function, but it remains unclear whether MEP monitoring can decrease the incidence of postoperative motor deficits. Therefore, we reviewed multicenter medical records of patients who had undergone descending and thoracoabdominal aortic repair (both open surgery and endovascular repair) to assess the association of MEP monitoring with postoperative motor deficits.
METHODS
Patients included in the study underwent descending or thoracoabdominal aortic repair at 12 hospitals belonging to the Japanese Association of Spinal Cord Protection in Aortic Surgery between 2000 and 2013. Using multivariable mixed-effects logistic regression analysis, we investigated whether intraoperative MEP monitoring was associated with postoperative motor deficits at discharge after open and endovascular aortic repair.
RESULTS
We reviewed data from 1214 patients (open surgery, 601 [49.5%]; endovascular repair, 613 [50.5%]). MEP monitoring was performed in 631 patients and not performed in the remaining 583 patients. Postoperative motor deficits were observed in 75 (6.2%) patients at discharge. Multivariable logistic regression analysis revealed that postoperative motor deficits at discharge did not have a significant association with MEP monitoring (adjusted odds ratio [OR], 1.13; 95% confidence interval [CI], 0.69-1.88; P = .624), but with other factors: history of neural deficits (adjusted OR, 6.08; 95% CI, 3.10-11.91; P < .001), spinal drainage (adjusted OR, 2.14; 95% CI, 1.32-3.47; P = .002), and endovascular procedure (adjusted OR, 0.45; 95% CI, 0.27-0.76; P = .003). The sensitivity and specificity of MEP <25% of control value for motor deficits at discharge were 37.8% (95% CI, 26.5%-49.5%) and 95.5% (95% CI, 94.7%-96.4%), respectively.
CONCLUSIONS
MEP monitoring was not significantly associated with motor deficits at discharge.