Increased colorectal permeability in patients with severe sepsis and septic shock.
Аннотация
OBJECTIVE
To develop a method for the assessment of colorectal permeability in septic patients.
DESIGN AND
SETTING
Observational study in ICUs at two university hospitals.
PARTICIPANTS
Nine patients with septic shock and abdominal focus of infection, 7 with severe sepsis and pulmonary focus and 8 healthy subjects.
MEASUREMENTS AND
RESULTS
Colorectal permeability was assessed as the initial appearance rate of (99m)Tc-DTPA in plasma after instillation into the rectal lumen and as the cumulative systemic recovery at 1h. To calculate the latter, volume of distribution and renal clearance of (99m)Tc-DTPA was estimated by an i.v. bolus of (51)Cr-EDTA. The initial rate of permeability was increased in patients with septic shock and severe sepsis compared with controls [29.0 (3.7-83.3), 20.6 (3.6-65.5) and 6.0 (2.2-9.6)cpm ml(-1)min(-1), respectively, p<0.05)] with a positive linear trend (r (2)=0.27, p=0.01) and correlated to L-lactate concentrations in the rectal lumen (r (2)=0.39, p<0.05). The cumulative permeability was also increased in patients with septic shock and severe sepsis compared with controls [2.07 (0.05-15.7), 0.32 (0.01-1.2) and 0.03 (0.01-0.06) per thousand, respectively, p<0.01] and correlated to the initial permeability rate (r (2)=0.26, p=0.01).
CONCLUSIONS
In septic patients, the systemic recovery of a luminally applied marker of paracellular permeability was increased and related to the luminal concentrations of L-lactate and possibly to disease severity. This suggests that the assessment of colorectal permeability by systemic recovery of (99m)Tc-DTPA is valid and that metabolic dysfunction of the mucosa contributes to increased permeability of the large bowel in patients with severe sepsis and septic shock.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.