Development of a high-specificity sandwich ELISA system for the quantification of human intestinal fatty acid-binding protein (I-FABP) concentrations.

Funaoka Hiroyuki, Kanda Tatsuo, Kajiura Satoshi, Ohkaru Yasuhiko, Fujii Hiroshi

СтатьяПеревод в очереди

Аннотация

Intestinal fatty acid-binding protein (I-FABP), a low molecular mass (approximately 15 kDa) cytoplasmic protein, is specifically located in epithelial cells of small bowel mucosal layer. This protein is rapidly released into the circulation after injury and/or destruction of these cells due to poor mesenteric blood flow and necrosis. Therefore, it can be used as a potential diagnostic biomarker for small bowel disease. In the present study, we have succeeded in developing a sandwich enzyme-linked immunosorbent assay (ELISA) system for quantification of human I-FABP. The range of sandwich ELISA system was 0.1-50 ng/mL of I-FABP in serum, and showed excellent quantitative characteristics such as reproducibility, dilution linearity, and recovery. No cross-reactivities were detected with other types of FABPs. As measured with this ELISA system, the serum I-FABP concentration was 1.1 ± 0.9 ng/mL in 61 healthy individuals, indicating that the reference value was below 2.0 ng/mL regardless of gender and age. Furthermore, mild abdominal pain or diarrhea before blood sampling did not affect I-FABP levels. Thus, this ELISA system could be used to accurately quantify human I-FABP concentrations in serum samples. These results suggest that it could be used as a new biomarker for the diagnosis of small bowel disease.

Для цитирования: Funaoka Hiroyuki, Kanda Tatsuo, Kajiura Satoshi, Ohkaru Yasuhiko, Fujii Hiroshi. Development of a high-specificity sandwich ELISA system for the quantification of human intestinal fatty acid-binding protein (I-FABP) concentrations.. Immunological investigations. 2011. DOI: 10.3109/08820139.2010.534216.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.