MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/01.shk.0000226338.48033.c2

Медицинская библиотека · Shock (Augusta, Ga.) · 2006

Bovine polymerized hemoglobin versus Hextend resuscitation in a swine model of severe controlled hemorrhagic shock with delay to definitive care.

Rice Jennifer, Philbin Nora, McGwin Gerald, Arnaud Françoise, Johnson Todd, Flournoy W Shannon, Pearce L Bruce, McCarron Richard, Kaplan Lew, Handrigan Michael, Freilich Daniel

Сравнительное исследованиеСтатьяПоддержка правительства СШАПеревод в очереди

Аннотация

To compare the efficacy of low-volume resuscitation with bovine polymerized hemoglobin (HBOC-201) versus hetastarch (HEX) in an intermediate severity combat-relevant hemorrhagic shock swine model with a simulated delay to hospital care. Twenty-four anesthetized pigs were hemorrhaged 55% estimated blood volume in conjunction with a 5-min rectus abdominus crush. At 20 min, pigs were resuscitated with 10 mL/kg of HBOC-201 or HEX or nothing (NON); resuscitated pigs received additional infusions (5 mL/kg) at 30, 60, 120, or 180 min if hypotension or tachycardia persisted. Pigs were monitored for a 4-h "prehospital" period. At 4-h, hospital arrival was simulated: surgical sites were repaired, blood, or saline provided, and pigs were recovered from anesthesia. Pigs were monitored for 72 h and then killed for histological evaluation. One hundred percent (8/8) of HBOC-201-, 75% (6/8) of HEX-, and 25% (2/8) of NON-resuscitated pigs survived to 72 h (P = 0.007 overall, HBOC vs. HEX P > 0.05). Mean arterial pressure and mean pulmonary arterial pressure were highest in the HBOC-201 group (P < 0.001), and HR was lowest (P < 0.001). HBOC-201- and HEX-resuscitated pigs had comparable cardiac index and prehospital fluid requirements. HBOC-201 pigs had higher transcutaneous tissue oxygen tension, P < 0.001) and lower urine output (P < 0.001). At simulated hospital arrival, no HBOC-201 pigs required additional fluids or blood transfusion. In contrast, 100% of HEX pigs required blood transfusions (P < 0.01). In this swine model of controlled hemorrhage with low-volume resuscitation and delayed definitive care, HBOC-201 pigs had improved hemodynamics, transcutaneous tissue oxygen tension, and transfusion avoidance compared with HEX.

Для цитирования: Rice Jennifer, Philbin Nora, McGwin Gerald, Arnaud Françoise, Johnson Todd, Flournoy W Shannon, Pearce L Bruce, McCarron Richard, Kaplan Lew, Handrigan Michael, Freilich Daniel. Bovine polymerized hemoglobin versus Hextend resuscitation in a swine model of severe controlled hemorrhagic shock with delay to definitive care.. Shock (Augusta, Ga.). 2006. DOI: 10.1097/01.shk.0000226338.48033.c2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.