m+Medelevator.RU
← Поиск публикаций
International journal of chronic obstructive pulmonary disease · 2012

Sputum eosinophilia can predict responsiveness to inhaled corticosteroid treatment in patients with overlap syndrome of COPD and asthma.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kitaguchi Yoshiaki, Komatsu Yoshimichi, Fujimoto Keisaku, Hanaoka Masayuki, Kubo Keishi

Аннотация

BACKGROUND: Chronic obstructive pulmonary disease (COPD) and asthma may overlap and converge in older people (overlap syndrome). It was hypothesized that patients with overlap syndrome may have different clinical characteristics such as sputum eosinophilia, and better responsiveness to treatment with inhaled corticosteroid (ICS).

METHODS: Sixty-three patients with stable COPD (forced expiratory volume in 1 second [FEV(1)] ≤80%) underwent pulmonary function tests, including reversibility of airflow limitation, arterial blood gas analysis, analysis of inflammatory cells in induced sputum, and chest high-resolution computed tomography. The inclusion criteria for COPD patients with asthmatic symptoms included having asthmatic symptoms such as episodic breathlessness, wheezing, cough, and chest tightness worsening at night or in the early morning (COPD with asthma group). The clinical features of COPD patients with asthmatic symptoms were compared with those of COPD patients without asthmatic symptoms (COPD without asthma group).

RESULTS: The increases in FEV(1) in response to treatment with ICS were significantly higher in the COPD with asthma group. The peripheral eosinophil counts and sputum eosinophil counts were significantly higher. The prevalence of patients with bronchial wall thickening on chest high-resolution computed tomography was significantly higher. A significant correlation was observed between the increases in FEV(1) in response to treatment with ICS and sputum eosinophil counts, and between the increases in FEV(1) in response to treatment with ICS and the grade of bronchial wall thickening. Receiver operating characteristic curve analysis revealed 82.4% sensitivity and 84.8% specificity of sputum eosinophil count for detecting COPD with asthma, using 2.5% as the cutoff value.

CONCLUSION: COPD patients with asthmatic symptoms had some clinical features. ICS should be considered earlier as a potential treatment in such patients. High sputum eosinophil counts and bronchial wall thickening on chest high-resolution computed tomography might therefore be a good predictor of response to ICS.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты