MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajic.2015.05.042

Медицинская библиотека · American journal of infection control · 2015

Clinical impact and cost-effectiveness of split-septum and single-use prefilled flushing device vs 3-way stopcock on central line-associated bloodstream infection rates in India: a randomized clinical trial conducted by the International Nosocomial Infection Control Consortium (INICC).

Rosenthal Victor Daniel, Udwadia Farokh Earch, Kumar Siva, Poojary Aruna, Sankar Rathi, Orellano Pablo Wenceslao, Durgad Shilpa, Thulasiraman Mahendran, Bahirune Shweta, Kumbhar Shubhangi, Patil Priyanka

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Three-way stopcocks (3WSCs) are open systems used on intravenous tubing. Split septums (SSs) are closed systems with prepierced septums. Single-use prefilled flushing devices (SUFs) carry a lower risk of contamination than standard intravenous flushing. 3WSC and standard flushing are widely used in developing countries. This is the first randomized clinical trial (RCT) to compare rates of central line-associated bloodstream infection (CLABSI) between patients using an SS + SUF and those using a 3WSC.

METHODS

An RCT with 1096 patients in 5 adult intensive care units was conducted between April 2012 and August 2014 to evaluate their impact on CLABSI rates. Centers for Disease Control and Prevention/National Healthcare Safety Network definitions were applied and International Nosocomial Infection Control Consortium methodology were followed.

RESULTS

The study cohort included 547 patients and 3619 central line (CL)-days for the SS + SUF group, and 549 patients and 4061 CL-days for the 3WSC group. CLABSI rates were 2.21 per 1000 CL-days for SS + SUF and 6.40 per 1000 CL-days for 3WSC (relative risk, 0.35; 95% confidence interval [CI], 0.16-0.76; P = .006). The SS + SUF group had significantly better cumulative infection-free catheter survival compared with the 3WSC group (hazard ration, 0.33; 95% CI, 0.15-0.73; P = .006). Using an SS + SUF represents savings of $402.88 and an increase in quality-adjusted life years of 0.0008 per patient. For each extra dollar invested in an SS + SUF, $124 was saved.

CONCLUSION

The use of SS + SUF is cost-effective and associated with a significantly lower CLABSI rate compared with the use of 3WSC.

Для цитирования: Rosenthal Victor Daniel, Udwadia Farokh Earch, Kumar Siva, Poojary Aruna, Sankar Rathi, Orellano Pablo Wenceslao, Durgad Shilpa, Thulasiraman Mahendran, Bahirune Shweta, Kumbhar Shubhangi, Patil Priyanka. Clinical impact and cost-effectiveness of split-septum and single-use prefilled flushing device vs 3-way stopcock on central line-associated bloodstream infection rates in India: a randomized clinical trial conducted by the International Nosocomial Infection Control Consortium (INICC).. American journal of infection control. 2015. DOI: 10.1016/j.ajic.2015.05.042.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.