MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.saa.2015.07.099

Медицинская библиотека · Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2015

Novel ratio difference at coabsorptive point spectrophotometric method for determination of components with wide variation in their absorptivities.

Saad Ahmed S, Abo-Talib Nisreen F, El-Ghobashy Mohamed R

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

Different methods have been introduced to enhance selectivity of UV-spectrophotometry thus enabling accurate determination of co-formulated components, however mixtures whose components exhibit wide variation in absorptivities has been an obstacle against application of UV-spectrophotometry. The developed ratio difference at coabsorptive point method (RDC) represents a simple effective solution for the mentioned problem, where the additive property of light absorbance enabled the consideration of the two components as multiples of the lower absorptivity component at certain wavelength (coabsorptive point), at which their total concentration multiples could be determined, whereas the other component was selectively determined by applying the ratio difference method in a single step. Mixture of perindopril arginine (PA) and amlodipine besylate (AM) figures that problem, where the low absorptivity of PA relative to AM hinders selective spectrophotometric determination of PA. The developed method successfully determined both components in the overlapped region of their spectra with accuracy 99.39±1.60 and 100.51±1.21, for PA and AM, respectively. The method was validated as per the USP guidelines and showed no significant difference upon statistical comparison with reported chromatographic method.

Для цитирования: Saad Ahmed S, Abo-Talib Nisreen F, El-Ghobashy Mohamed R. Novel ratio difference at coabsorptive point spectrophotometric method for determination of components with wide variation in their absorptivities.. Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy. 2015. DOI: 10.1016/j.saa.2015.07.099.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.