MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/chromsci/bmae024

Медицинская библиотека · Journal of chromatographic science · 2024

Development of Response Surface Approach for Determination of Paracetamol, Chlorpheniramine Maleate, Caffeine and Ascorbic Acid by Green HPLC Method: A Desirability-Based Optimization.

Mouhamed Aya A, Eltanany Basma M, Mostafa Nadia M, Nadim Ahmed H

СтатьяПеревод в очереди

Аннотация

Design of experiment is an efficient and cost-effective tool to optimize the chromatographic separation of a multicomponent mixture. The central composite design was conducted to develop and optimize a green high performance liquid chromatography (HPLC) method for simultaneous quantitation of a quaternary mixture of paracetamol, chlorpheniramine maleate, caffeine and ascorbic acid in their pharmaceutical dosage form as well as the determination of their dissolution profile. A five-level three-factor model was performed to investigate the effect of mobile phase composition, pH and flow rate on enhanced resolution and short run time. Analysis was performed using a Kinitex EVO C18 column and a mobile phase composed of methanol: 0.02 M phosphate buffer pH 3.3 (34:66, v/v) at 1.0 mL/min using photodiode array detection. Optimum chromatographic separation was achieved in <6 min with a desirability of 0.999. Linearity was achieved over a range of 1.00-300.00, 1.00-50.00, 2.00-50.00 and 2.00-100.00 μg/mL for paracetamol, chlorpheniramine maleate, caffeine and ascorbic acid, respectively, with a limit of detection (<0.1 μg/mL). The greenness profile was evaluated using the analytical eco-scale and Analytical GREEnness Metric Approach with values of 81 and 0.77, respectively.

Для цитирования: Mouhamed Aya A, Eltanany Basma M, Mostafa Nadia M, Nadim Ahmed H. Development of Response Surface Approach for Determination of Paracetamol, Chlorpheniramine Maleate, Caffeine and Ascorbic Acid by Green HPLC Method: A Desirability-Based Optimization.. Journal of chromatographic science. 2024. DOI: 10.1093/chromsci/bmae024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.