MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.sapharm.2024.08.090

Медицинская библиотека · Research in social & administrative pharmacy : RSAP · 2024

Concordance between pharmacy dispensing and electronic monitoring data of direct oral anticoagulants - A secondary analysis of the MAAESTRO study.

Barbati Selina, Baumgartner Pascal C, Dietrich Fine, Allemann Samuel S, Arnet Isabelle

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Direct oral anticoagulants are the preferred treatment for stroke patients with atrial fibrillation. Pharmacy dispensing data represent a practical method to identify suboptimal medication adherence.

OBJECTIVE

This study investigates whether pharmacy dispensing data are indicative of real-life adherence behavior, using data from 130 patients in the MAAESTRO study (2018-2022) in Basel, Switzerland.

METHODS

This secondary data analysis of the MAAESTRO study (Dietrich, 2024) included patients with electronic monitoring (EM) and dispensing data for 12 months. Patients with at least two refills were included in the analysis. We categorized refill series into three adherence patterns using the Delta T method (Baumgartner, 2022): all refills on time, erratic refills, end-gaps ≥10 days. EM-adherence was assessed through "taking adherence" and "missing days" (24h without intake). We analyzed: i) all dispensing data ("all refills"); ii) all data independently of the MAAESTRO phase ("all phases"); iii) the last two dispensing data ("last"), and iv) EM data from the MAAESTRO phase that match the date of the last refill ("matched"). Associations between refill patterns and adherence were examined using Spearman correlation and Fisher's exact test.

RESULTS

Data analyzed from 50 patients (mean age 76.4 ± 9.1 years, 56.0 % male) included 252 refills with a median of 4 refills per patient. Refill patterns were: all refills on time (40.0 %), erratic refills (36.0 %), and end-gaps >10 days (24.0 %). Mean taking adherence was 89.3 ± 13.7 %. EM data revealed missing days in 82.0 % of patients, with 61.0 % having irregular refill patterns. Matched taking adherence was moderately associated with Delta T over all refills (p = 0.034) and the last refill (p = 0.013).

CONCLUSIONS

Dispensing data processed with the Delta T method correlate moderately with EM data. The Delta T value for the last two refills shows promise for estimating irregular adherence, suggesting potential for targeted interventions in pharmacy practice.

Для цитирования: Barbati Selina, Baumgartner Pascal C, Dietrich Fine, Allemann Samuel S, Arnet Isabelle. Concordance between pharmacy dispensing and electronic monitoring data of direct oral anticoagulants - A secondary analysis of the MAAESTRO study.. Research in social & administrative pharmacy : RSAP. 2024. DOI: 10.1016/j.sapharm.2024.08.090.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.