Assessing Fetal Cardiac Function by Measuring Myocardial Radial Velocity Using the Phased-Tracking Method.

Ozawa Katsusuke, Murotsuki Jun, Miyashita Susumu, Muromoto Jin, Hasegawa Hideyuki, Kanai Hiroshi, Yaegashi Nobuo

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

This study aimed to assess the cardiac function of healthy and pathological fetuses by measuring radial velocity using phased tracking (PT). Based on phase differences, PT allows the displacement of a specified point to be detected with improved spatial and temporal resolution.

METHODS

PT was used to assess cardiac radial velocity in the basal free wall of the left and right ventricles in 134 healthy fetuses, 10 second-trimester intrauterine growth-restricted (IUGR) fetuses, and 10 recipient twins with twin-to-twin transfusion syndrome (TTTS). Maximum velocities were measured in systole and early diastole.

RESULTS

Maximum radial velocity was successfully measured in 126 healthy fetuses (94%) at gestational ages of 16-40 weeks. Systolic and early diastolic maximum velocities increased with gestational age in both ventricles. As compared with controls, IUGR fetuses had significantly lower early diastolic maximum velocities in the right ventricle, and recipient twins with TTTS had significantly lower systolic and early diastolic maximum velocities in both ventricles.

CONCLUSIONS

PT demonstrated right ventricular diastolic dysfunction in second-trimester IUGR fetuses as well as systolic and diastolic dysfunctions in both ventricles in recipient twins with TTTS. PT could be useful for evaluating fetal cardiac radial function.

Для цитирования: Ozawa Katsusuke, Murotsuki Jun, Miyashita Susumu, Muromoto Jin, Hasegawa Hideyuki, Kanai Hiroshi, Yaegashi Nobuo. Assessing Fetal Cardiac Function by Measuring Myocardial Radial Velocity Using the Phased-Tracking Method.. Fetal diagnosis and therapy. 2015. DOI: 10.1159/000371514.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.