MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmr.2012.01.019

Медицинская библиотека · Journal of magnetic resonance (San Diego, Calif. : 1997) · 2012

W-band PELDOR with 1 kW microwave power: molecular geometry, flexibility and exchange coupling.

Reginsson Gunnar W, Hunter Robert I, Cruickshank Paul A S, Bolton David R, Sigurdsson Snorri Th, Smith Graham M, Schiemann Olav

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A technique that is increasingly being used to determine the structure and conformational flexibility of biomacromolecules is Pulsed Electron-Electron Double Resonance (PELDOR or DEER), an Electron Paramagnetic Resonance (EPR) based technique. At X-band frequencies (9.5 GHz), PELDOR is capable of precisely measuring distances in the range of 1.5-8 nm between paramagnetic centres but the orientation selectivity is weak. In contrast, working at higher frequencies increases the orientation selection but usually at the expense of decreased microwave power and PELDOR modulation depth. Here it is shown that a home-built high-power pulsed W-band EPR spectrometer (HiPER) with a large instantaneous bandwidth enables one to achieve PELDOR data with a high degree of orientation selectivity and large modulation depths. We demonstrate a measurement methodology that gives a set of PELDOR time traces that yield highly constrained data sets. Simulating the resulting time traces provides a deeper insight into the conformational flexibility and exchange coupling of three bisnitroxide model systems. These measurements provide strong evidence that W-band PELDOR may prove to be an accurate and quantitative tool in assessing the relative orientations of nitroxide spin labels and to correlate those orientations to the underlying biological structure and dynamics.

Для цитирования: Reginsson Gunnar W, Hunter Robert I, Cruickshank Paul A S, Bolton David R, Sigurdsson Snorri Th, Smith Graham M, Schiemann Olav. W-band PELDOR with 1 kW microwave power: molecular geometry, flexibility and exchange coupling.. Journal of magnetic resonance (San Diego, Calif. : 1997). 2012. DOI: 10.1016/j.jmr.2012.01.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.