Ultrasensitive Ion Source for Drift Tube Ion Mobility Spectrometers Combining Optimized Sample Gas Flow with Both Chemical Ionization and Direct Ionization.

Kirk Ansgar T, Kueddelsmann Maximilian J, Zimmermann Stefan

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Efficient ionization of analyte molecules is a crucial step for the outstanding sensitivity of ion mobility spectrometers (IMS) used for trace gas detection. Here, we present a new ion source that combines the previously published extended field switching ion shutter with two switchable ionization sources and an optimized sample gas flow that leads to a focused laminar stream through the reaction region of the ion source. The X-ray ionization source allows for chemical gas phase ionization of analyte molecules, while the UV ionization source allows for direct ionization of analyte molecules. The optimized sample gas flow not only allows for quickly washing out analyte molecules from the reaction region but also has improved sensitivity by a factor of about 5 for protonated monomers, 20 for proton-bound dimers, and over 100 for the proton-bound trimer of 1-octanol. The resulting limits of detection using chemical X-ray ionization are in the subpptv-range for protonated monomers and in the low pptv-range for proton-bound dimers, while the limits of detection using direct UV ionization are in the subppbv-range. Especially, a direct comparison between chemical and direct ionization of ketones using this ultrasensitive ion source reveals a stepwise conversion from directly ionized monomers to proton-bound dimers via protonated monomers during direct UV ionization.

Для цитирования: Kirk Ansgar T, Kueddelsmann Maximilian J, Zimmermann Stefan. Ultrasensitive Ion Source for Drift Tube Ion Mobility Spectrometers Combining Optimized Sample Gas Flow with Both Chemical Ionization and Direct Ionization.. Analytical chemistry. 2022. DOI: 10.1021/acs.analchem.2c00955.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.