MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1152/jappl.1990.69.3.962

Медицинская библиотека · Journal of applied physiology (Bethesda, Md. : 1985) · 1990

Comparison of phenylephrine bolus and infusion methods in baroreflex measurements.

Sullebarger J T, Liang C S, Woolf P D, Willick A E, Richeson J F

Сравнительное исследованиеСтатьяПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

Phenylephrine (PE) bolus and infusion methods have both been used to measure baroreflex sensitivity in humans. To determine whether the two methods produce the same values of baroreceptor sensitivity, we administered intravenous PE by both bolus injection and graded infusion methods to 17 normal subjects. Baroreflex sensitivity was determined from the slope of the linear relationship between the cardiac cycle length (R-R interval) and systolic arterial pressure. Both methods produced similar peak increases in arterial pressure and reproducible results of baroreflex sensitivity in the same subjects, but baroreflex slopes measured by the infusion method (9.9 +/- 0.7 ms/mmHg) were significantly lower than those measured by the bolus method (22.5 +/- 1.8 ms/mmHg, P less than 0.0001). Pretreatment with atropine abolished the heart rate response to PE given by both methods, whereas plasma catecholamines were affected by neither method of PE administration. Naloxone pretreatment exaggerated the pressor response to PE and increased plasma beta-endorphin response to PE infusion but had no effect on baroreflex sensitivity. Thus our results indicate that 1) activation of the baroreflex by the PE bolus and infusion methods, although reproducible, is not equivalent, 2) baroreflex-induced heart rate response to a gradual increase in pressure is less than that seen with a rapid rise, 3) in both methods, heart rate response is mediated by the vagus nerves, and 4) neither the sympathetic nervous system nor the endogenous opiate system has a significant role in mediating the baroreflex control of heart rate to a hypertensive stimulus in normal subjects.

Для цитирования: Sullebarger J T, Liang C S, Woolf P D, Willick A E, Richeson J F. Comparison of phenylephrine bolus and infusion methods in baroreflex measurements.. Journal of applied physiology (Bethesda, Md. : 1985). 1990. DOI: 10.1152/jappl.1990.69.3.962.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.