MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mlg.0b013e3181856051

Медицинская библиотека · The Laryngoscope · 2008

Modeling flow in a compromised pediatric airway breathing air and heliox.

Mihaescu Mihai, Gutmark Ephraim, Murugappan Shanmugam, Elluru Ravindhra, Cohen Aliza, Willging J Paul

СтатьяПеревод в очереди

Аннотация

OBJECTIVES/HYPOTHESIS: The aim of this study was to perform computer simulations of flow within an accurate model of a pediatric airway with subglottic stenosis. It is believed that the airflow characteristics in a stenotic airway are strongly related to the sensation of dyspnea.

METHODOLOGY: Computed tomography images through the respiratory tract of an infant with subglottic stenosis, were used to construct the three-dimensional geometry of the airway. By using computational fluid dynamics (CFD) modeling to capture airway flow patterns during inspiration and expiration, we obtained information pertaining to flow velocity, static airway wall pressure, pressure drop across the stenosis, and wall shear stress. These simulations were performed with both air and heliox.

RESULTS

Unlike air, heliox maintained laminar flow through the stenosis. The calculated pressure drop over stenosis was lower for the heliox flow, in contrast to the airflow case. This lead to an approximately 40% decrease in airway resistance when using heliox, and presumably causes a decrease in the level of effort required for breathing.

CONCLUSIONS

CFD simulations offer a quantitative method of evaluating airway flow dynamics in patients with airway abnormalities. CFD modeling illustrated the flow features and quantified flow parameters within a pediatric airway with subglottic stenosis. Simulations with air and heliox conditions mirrored the known clinical benefits of heliox as compared with air. We anticipate that computer simulation models will ultimately allow a better understanding of changes in flow caused by specific medical and surgical interventions in patients with conditions associated with dyspnea.

Для цитирования: Mihaescu Mihai, Gutmark Ephraim, Murugappan Shanmugam, Elluru Ravindhra, Cohen Aliza, Willging J Paul. Modeling flow in a compromised pediatric airway breathing air and heliox.. The Laryngoscope. 2008. DOI: 10.1097/mlg.0b013e3181856051.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.