MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0018720820916629

Медицинская библиотека · Human factors · 2020

In Situ Tremor in Vitreoretinal Surgery.

Li Yifan, Wolf Mitchell D, Kulkarni Amol D, Bell James, Chang Jonathan S, Nimunkar Amit, Radwin Robert G

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Surgeon tremor was measured during vitreoretinal microscopic surgeries under different hand support conditions.

BACKGROUND

While the ophthalmic surgeon's forearm is supported using a standard symmetric wrist rest when operating on the patient's same side as the dominant hand (SSD), the surgeon's hand is placed directly on the patient's forehead when operating on the contralateral side of the dominant hand (CSD). It was hypothesized that more tremor is associated with CSD surgeries than SSD surgeries and that, using an experimental asymmetric wrist rest where the contralateral wrist bar gradually rises and curves toward the patient's operative eye, there is no difference in tremor associated with CSD and SSD surgeries.

METHODS

Seventy-six microscope videos, recorded from three surgeons performing macular membrane peeling operations, were analyzed using marker-less motion tracking, and movement data (instrument path length and acceleration) were recorded. Tremor acceleration frequency and magnitude were measured using spectral analysis. Following 47 surgeries using a conventional symmetric wrist support, surgeons incorporated the experimental asymmetric wrist rest into their surgical routine.

RESULTS

There was 0.11 mm/s2 (22%) greater (p = .05) average tremor acceleration magnitude for CSD surgeries (0.62 mm/s2, SD = 0.08) than SSD surgeries (0.51 mm/s2, SD = 0.09) for the symmetric wrist rest, while no significant (p > .05) differences were observed (0.57 mm, SD = 0.13 for SSD and 0.58 mm, SD = 0.11 for CSD surgeries) for the experimental asymmetric wrist rest.

CONCLUSION

The asymmetric wrist support reduced the difference in tremor acceleration between CSD and SSD surgeries.

Для цитирования: Li Yifan, Wolf Mitchell D, Kulkarni Amol D, Bell James, Chang Jonathan S, Nimunkar Amit, Radwin Robert G. In Situ Tremor in Vitreoretinal Surgery.. Human factors. 2020. DOI: 10.1177/0018720820916629.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.