MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2106/jbjs.j.01705

Медицинская библиотека · The Journal of bone and joint surgery. American volume · 2011

Medial portal drilling: effects on the femoral tunnel aperture morphology during anterior cruciate ligament reconstruction.

Hensler Daniel, Working Zachary M, Illingworth Kenneth D, Thorhauer Eric D, Tashman Scott, Fu Freddie H

СтатьяОбзорПеревод в очереди

Аннотация

BACKGROUND

A goal of anatomic anterior cruciate ligament (ACL) reconstruction should be to create a femoral tunnel aperture that resembles the native attachment site in terms of size and orientation. Aperture morphology varies as a function of the drill-bit diameter, the angle in the horizontal plane at which the drilled tunnel intersects the lateral notch wall (transverse drill angle), and the angle of knee flexion in the vertical plane during drilling.

METHODS

A literature search was conducted to determine population-based dimensions of the femoral ACL footprint. The tunnel aperture length, width, and area associated with the use of different drill-bit diameters and transverse drill angles were calculated. The effect of the knee flexion angle on the orientation (anteroposterior and proximodistal dimension) and size of the femoral tunnel aperture relative to the native femoral insertion of the ACL were calculated with use of geometric mathematical models.

RESULTS

The literature search revealed an average femoral insertion site size of 8.9 mm for width, 16.3 mm for length, and 136.0 mm2 for area. The use of a 9-mm drill bit at a transverse drill angle of 40° resulted in a tunnel aperture area of 99.0 mm2 and a tunnel aperture length of 14.0 mm. Decreasing the transverse drill angle from 60° to 20° led to an increase of 152.9% in length and of 153.1% in tunnel aperture area. When a 9-mm drill bit and a transverse drill angle of 40° were used, the aperture seemed to best match the native ACL footprint when drilling was performed at a knee flexion angle of 102°; deviations from this angle in either direction resulted in increasing tunnel area mismatch compared with the baseline aperture. Increasing the knee flexion angle to 130° decreased the proximodistal dimension of the aperture by 2.78 mm and increased the anteroposterior distance by 0.65 mm, creating a mismatched area of 13.5%.

CONCLUSIONS

The drill-bit diameter, transverse drill angle, and knee flexion angle can all affect femoral tunnel aperture morphology in medial portal drilling during ACL reconstruction. The relationship between drilling orientation and aperture morphology is critical knowledge for surgeons performing ACL reconstruction.

Для цитирования: Hensler Daniel, Working Zachary M, Illingworth Kenneth D, Thorhauer Eric D, Tashman Scott, Fu Freddie H. Medial portal drilling: effects on the femoral tunnel aperture morphology during anterior cruciate ligament reconstruction.. The Journal of bone and joint surgery. American volume. 2011. DOI: 10.2106/jbjs.j.01705.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.