MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2106/jbjs.cc.21.00731

Медицинская библиотека · JBJS case connector · 2022

Hypersensitivity Reaction to Carbon Fiber-Polyetheretherketone Composite Spinal Implant: A Case Report.

Bueno Brian T, Henry Mark, Cho Samuel K

Клинический случайСтатьяПеревод в очереди

Аннотация

CASE: A 52-year-old woman presented with localized hypersensitivity symptoms immediately after insertion of a carbon fiber-polyetheretherketone (CF-PEEK) vertebral fusion device. After a modified cutaneous patch test confirmed an allergic reaction to the implant, the device was surgically removed. The patient's symptoms were largely resolved 1 month after the removal of the device.

CONCLUSION

CF-PEEK is a commonly used biomaterial in surgical implants. As far as we know, this is the first reported case of a hypersensitivity reaction to CF-PEEK.

Для цитирования: Bueno Brian T, Henry Mark, Cho Samuel K. Hypersensitivity Reaction to Carbon Fiber-Polyetheretherketone Composite Spinal Implant: A Case Report.. JBJS case connector. 2022. DOI: 10.2106/jbjs.cc.21.00731.