MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2463/mrms.mp.2019-0166

Медицинская библиотека · Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2020

Relationship between Measurement Errors in Myocardial T1 Mapping and Heart Rate.

Amano Yasuo, Omori Yuko, Yanagisawa Fumi, Ando Chisato, Shinoda Naoki, Suzuki Yasuyuki, Yamamoto Hiroshi, Matsumoto Naoya

СтатьяПеревод в очереди

Аннотация

PURPOSE: Modified Look-Locker inversion recovery (MOLLI) using a 5s(3s)3s scheme is robust to tachycardia, but some errors are occasionally observed in myocardial T1 mapping. We sought to evaluate the relationship between measurement errors in T1 mapping and heart rate (HR) using a confidence map.

METHODS

We enrolled 69 male patients with normal native T1 values of the septal myocardium measured by a 5s(3s)3s MOLLI. The degree of measurement errors in the septal myocardium was assessed by two independent observers on a confidence map using a 4-point scale: 0, no errors; 1, errors located on the myocardial contour; 2, errors extended into the myocardial contour; and 3, errors extended into the midwall. We compared the scores of measurement errors and the average, maximum, minimum or variability of the HR indicated during the MOLLI scan (iHR), image phases of MOLLI or left ventricular ejection fraction (LVEF).

RESULTS

Patients with score >1 for the septal myocardium had significantly lower minimum iHR than those with a score ≤1 (P < 0.01; 49.8 ± 10.1 vs. 59.6 ± 9.7 beat per min).

CONCLUSION

The confidence map shows more measurement errors in patients with lower minimum iHR. The myocardial T1 values should be measured carefully in patients with bradycardia during MOLLI scanning.

Для цитирования: Amano Yasuo, Omori Yuko, Yanagisawa Fumi, Ando Chisato, Shinoda Naoki, Suzuki Yasuyuki, Yamamoto Hiroshi, Matsumoto Naoya. Relationship between Measurement Errors in Myocardial T1 Mapping and Heart Rate.. Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine. 2020. DOI: 10.2463/mrms.mp.2019-0166.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.