MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Cardiovascular journal of South Africa : official journal for Southern Africa Cardiac Society [and] South African Society of Cardiac Practitioners · 2001

Diagnosis of haemodynamically significant patent ductus arteriosus in neonates-- is the ECG of diagnostic help?

Shipton S E, van der Merwe P L, Nel E D

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

The presence of a haemodynamically significant patent ductus arteriosis (PDA) in the premature newborn may contribute to the development of brochopulmonary dysplasia, intraventricular haemorrhage and necrotising enterocolitis. It is therefore essential that the diagnosis of such a PDA be made in time in order to intervene medically or surgically. Echocardiography is at present the prime diagnostic tool, but it is mainly available in tertiary hospitals. Chest roentgenography is of little diagnostic value especially in the presence of respiratory disease, which is often present in premature babies. Very little is known about the diagnostic value of the electrocardiogram (ECG) in premature babies. The aim of this study was to describe the standard 12-lead ECG findings in low-birth-weight babies with haemodynamically significant PDAs. Thirty-two babies with haemodynamically significant PDAs, as established by echocardiography, were included in the study. Standard 12-lead ECGs were done in all these babies. In 15 patients ECG abnormalities were found; only 22% had left atrial and left ventricular enlargement indicative of significant left-to-right shunting, while 78% had no ECG changes indicative of left-to-right shunting. In conclusion, the ECG cannot be used to identify haemodynamically significant PDAs.

Для цитирования: Shipton S E, van der Merwe P L, Nel E D. Diagnosis of haemodynamically significant patent ductus arteriosus in neonates-- is the ECG of diagnostic help?. Cardiovascular journal of South Africa : official journal for Southern Africa Cardiac Society [and] South African Society of Cardiac Practitioners. 2001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.