MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12882-024-03908-0

Медицинская библиотека · BMC nephrology · 2025

Correlation between intradialytic blood pressure variability and cognitive impairment in patients on maintenance hemodialysis.

Wan Jingfang, Liu Jun, Pan Jing, Fu Lili, He Dandan, Yao Yaru, He Yani, Chen Kehong

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The relationship between intradialytic blood pressure variability (BPV) and mild cognitive impairment (MCI) in maintenance hemodialysis (MHD) patients is currently unclear. Our present study aimed to illustrate the correlation between intra-dialysis BPV and CI in MHD patients.

METHODS

Intradialytic SBP within 3 months before cognitive assessment of the patients were collected as baseline data and averaged as final data. The intradialytic SBP was converted to the following 4 candidate short-term BPV indices: standard deviation (SD), coefficient of variation (CV), average real variability (ARV), RANGE. Overall cognitive function was assessed by the Montreal Cognitive Assessment (MoCA) scale.

RESULTS

The study finally enrolled 170 patients with 6662 dialysis records and 26,580 SBP measurements. The mean age of the patients was 57.99 years, the MCI prevalence was 78.24%. Intradialytic SBP ARV (average real variability) was notably higher in patients with MCI than in the non-MCI (NMCI) group (8.91 vs. 7.60, P = 0.042), but there was no statistical difference in the mean SBP and other BPV indices between the two groups. There was a non-linear relationship between SBP ARV and MCI, and the inflection point of SBP ARV was 7.52.

CONCLUSION

Our study found that high SBP ARV was closely associated with MCI, indicating that high SBP ARV may act as an indicator of MCI in MHD patients.

Для цитирования: Wan Jingfang, Liu Jun, Pan Jing, Fu Lili, He Dandan, Yao Yaru, He Yani, Chen Kehong. Correlation between intradialytic blood pressure variability and cognitive impairment in patients on maintenance hemodialysis.. BMC nephrology. 2025. DOI: 10.1186/s12882-024-03908-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.