m+Medelevator.RU
← Поиск публикаций
Surgical innovation · 2025

Validation of a Novel "Windshield Wiper" for Laparoscopes in Cadaver and Live Porcine Models.

СтатьяВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Idelson Christopher R, Campbell Etse-Oghena Y, Fuentes Lee M, Golestani Simin E, Ali Jawad T, Fagerberg Austin, Laviana Aaron, Uecker John M

Аннотация

BackgroundDuring laparoscopic surgeries, laparoscopes are inserted through a trocar port into the body cavity, which is then insufflated with carbon dioxide. Laparoscope lens clarity frequently becomes compromised via condensation or smearing of blood and adipose. This problem is well-known in the field, yet a viable in vivo solution has yet to address the issue and be successfully clinically adopted.Research DesignA structured cadaveric study evaluated the cleaning performance and clinician satisfaction with a novel laparoscope lens cleaning device against 2 gold-standard lens cleaning products. The novel device was also tested in a live animal porcine model to assess cleaning performance in a warm body environment qualitatively. The validation in the porcine model did not have the same evaluation process and comparison with other lens clearing methods as the cadaveric experiment.ResultsCleaning events were timed individually and analyzed post hoc. Average times to clean scopes for the novel device, Clearify™, and Fred™ Anti-Fog solution were 5 ± 5, 16 ± 7, and 14 ± 6 seconds, respectively. In 100 cleaning events with the novel device, the laparoscope was removed from the body zero times, with an average of 2 ± 1.29 cleaning actuations per event. Clearify™ and Fred™ Anti-Fog were removed from the body 102 and 116 times, with an average number of cleaning actuations of 1.07 ± 0.26 and 1.19 ± 0.53 per event, respectively. In the live porcine model, the novel device consistently cleared all debris deposited on the lens, including fog, tissue, blood, and bile fluid.ConclusionThis study demonstrates the novel device's reduction in cleaning duration and scope removals compared to gold-standard technologies, suggesting a potential for improved workflow and reduced intra-operative interruptions.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты