MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jpba.2006.04.013

Медицинская библиотека · Journal of pharmaceutical and biomedical analysis · 2006

Multicommuted flow system employing pinch solenoid valves and micro-pumps. Spectrophotometric determination of paracetamol in pharmaceutical formulations.

Lavorante André F, Pires Cherrine K, Reis Boaventura F

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A multicommuted spectrophotometric flow-based procedure for the determination of paracetamol in pharmaceutical formulations is proposed. The method is based on the reaction of paracetamol with sodium hypochlorite forming N-acetyl-p-benzoquinoneimine, which reacts with sodium salicylate in alkaline medium producing a blue indophenol dye that was measured at 640nm. The flow system was designed employing four pinch solenoid valves and two solenoid micro-pumps, which were assembled aiming to obtain a compact module, resulting in minimization of reagents consumption and waste generation. Aiming to prove the usefulness of flow system an analytical procedure for paracetamol determination in pharmaceutical formulations was developed. To allow accuracy assessment samples were also analyzed using the AOAC reference method. Applying the paired t-test between results no significant difference at the 95% confidence level was observed. Other profitable features such as a linear response ranging from 5.0 to 125.0mgl(-1) (R=0.9992, n=7), a sampling rate of 60 determinations per hour, a detection limit of 0.4mgl(-1) paracetamol, a relative standard deviation of 1.5% (n=11) for a typical sample solution containing 25.0mgl(-1) paracetamol, reagent consumption of 1.28mg sodium hypochlorite and 6.4mg sodium salicylate per determination were also achieved.

Для цитирования: Lavorante André F, Pires Cherrine K, Reis Boaventura F. Multicommuted flow system employing pinch solenoid valves and micro-pumps. Spectrophotometric determination of paracetamol in pharmaceutical formulations.. Journal of pharmaceutical and biomedical analysis. 2006. DOI: 10.1016/j.jpba.2006.04.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.