Lead configuration for defibrillator implantation in a patient with congenital heart disease and a mechanical prosthetic tricuspid valve.

Leng C T, Crosson J E, Calkins H, Berger R D

Клинический случайСтатьяПеревод в очереди

Аннотация

The authors devised a nonthoracotomy defibrillation system for a patient with a prosthetic tricuspid valve using existing technology and previously established implantation techniques. Their lead configuration deviates substantially from existing designs in its primary use of a coronary sinus defibrillation coil and a left-sided subcutaneous array to distribute current across the ventricular myocardium.

Для цитирования: Leng C T, Crosson J E, Calkins H, Berger R D. Lead configuration for defibrillator implantation in a patient with congenital heart disease and a mechanical prosthetic tricuspid valve.. Pacing and clinical electrophysiology : PACE. 2001. DOI: 10.1046/j.1460-9592.2001.01291.x.