m+Medelevator.RU
← Поиск публикаций
Surgical case reports · 2016

Thoracic endovascular aortic repair for complicated chronic type B aortic dissection in a patient on hemodialysis with recurrent ischemic colitis.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Miyazaki Yuko, Furuyama Tadashi, Matsubara Yutaka, Yoshiya Keiji, Yoshiga Ryosuke, Inoue Kentaro, Matsuda Daisuke, Aoyagi Yukihiko, Kato Masaaki, Matsumoto Takuya, Maehara Yoshihiko

Аннотация

We present a successful case of thoracic endovascular aortic repair (TEVAR) for chronic Stanford type B aortic dissection (B-AD) with recurrent ischemic colitis. The patient was a 56-year-old woman with abdominal pain as the main complaint who had two operations previously: the total arch replacement 8 years ago and the Bentall 7 years ago for acute Stanford type A aortic dissection. Her abdominal pain worsened as her blood pressure became low during her hemodialysis treatment. An enhanced computed tomography scan was performed on the patient and showed chronic B-AD that occurred from the distal anastomotic part of the total arch graft to the bilateral common iliac arteries. The celiac artery and superior mesenteric artery (SMA) arose from the true lumen, and these were compressed by the expanded false lumen. Her complicated chronic B-AD was treated with the Zenith Dissection Endovascular System, and its procedure was performed as her proximal entry tear was covered by a proximal tapered Zenith TX2 stent graft, supplemented by a noncovered aortic stent extending across both renal arteries, the SMA, and the celiac artery. Seven days after this operation, enhanced computed tomography showed that the patient's true lumen was expanded and her blood flow to the true lumen and SMA was improved. On the other hand, her false lumen tended to be thrombosed. Consequently, she was discharged 10 days after the operation without any postoperative complications as she had no abdominal complaints even though she underwent hemodialysis three times per week after the operation. We believe that TEVAR supplemented by a noncovered aortic stent is an effective treatment, even for highly chronic B-AD in dialysis patients.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты