MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cca.2023.117414

Медицинская библиотека · Clinica chimica acta; international journal of clinical chemistry · 2023

The impact of inter-laboratory glucose bias on the diagnosis of gestational diabetes mellitus: Comparison of common automated central laboratory methods.

Scheuer Cathrine Munk, Tvarnø Casper Duevang, Gils Charlotte, Ravn Julie Dahl, David McIntyre H, Jensen Dorte Møller, Damm Peter, Lauenborg Jeannet Kepp Bruun, Clausen Tine Dalsgaard, Overgaard Martin

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND AIMS: The diagnosis of gestational diabetes mellitus (GDM) is based exclusively on glucose measurements, which are highly influenced by pre-analytical and analytical factors. Therefore, poor agreement across laboratories may affect the prevalence of GDM. We aimed to determine the inter-laboratory bias of glucose measurements and the impact on GDM prevalence.

MATERIAL AND

METHODS

A prospective cohort study of women (n = 110) referred for second-trimester GDM diagnostics using a 75 g oral glucose tolerance test. Maternal glucose was assessed from venous plasma at fasting, 1 h and 2 h. Venous blood were collected in Fluoride Citrate tubes and frozen. Samples were analyzed at five central laboratories using four different automated glucose Hexokinase methods and GDM prevalence was evaluated according to WHO2013 diagnostic criteria.

RESULTS

Maximum inter-laboratory bias was 0.19, 0.30 and 0.27 mmol/L in fasting, 1 h and 2 h samples, respectively. GDM prevalence ranged 30.0-41.1% across laboratories.

CONCLUSION

Inter-laboratory bias for mean venous glucose was low and within desirable limits. Nonetheless, the impact on GDM prevalence was considerable, which may inappropriately affect clinical practice.

Для цитирования: Scheuer Cathrine Munk, Tvarnø Casper Duevang, Gils Charlotte, Ravn Julie Dahl, David McIntyre H, Jensen Dorte Møller, Damm Peter, Lauenborg Jeannet Kepp Bruun, Clausen Tine Dalsgaard, Overgaard Martin. The impact of inter-laboratory glucose bias on the diagnosis of gestational diabetes mellitus: Comparison of common automated central laboratory methods.. Clinica chimica acta; international journal of clinical chemistry. 2023. DOI: 10.1016/j.cca.2023.117414.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.