Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2020

Short- and mid-term influence of drug-coated stent implantation on structural and functional vascular healing response: An optical coherence tomography and acetylcholine testing study.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tamaru Hiroto, Fujii Kenichi, Otsuji Satoru, Takiuchi Shin, Hasegawa Katsuyuki, Ishibuchi Kasumi, Ishii Rui, Yamamoto Wataru, Nakabayashi Sho, Higashino Yorihiko

Аннотация

OBJECTIVE: This study investigated the effect of a drug-coated stent (DCS) that has a novel microporous abluminal surface without a polymer on 1-month and 1-year functional and morphological healing response as assessed using acetylcholine (Ach) testing and optical coherence tomography (OCT).

BACKGROUND: DCS is expected to induce favorable morphological and physiological arterial healing after its implantation.

METHODS: A total of 11 patients who underwent vascular response examinations 1-month and 1-year after the index PCI with DCS implantation were enrolled. The vascular response was evaluated by the functional response test by acetylcholine infusion, the morphological response test by OCT.

RESULTS: Although 94.5% of the DCS struts were covered by homogeneous smooth neointima at 1 month, the percentage of neointimal coverage increased to 98.5% at 1 year (p = .02). Conversely, the proportion of uncovered struts and malapposed struts at 1 year were 1.2 and 0.7%, respectively. Furthermore, the coronary vasomotor response to incremental doses of Ach were impaired especially in the distal segments at each period, although the responses to Ach at 10-6  mol/L in the distal segment tended to improve over time from baseline to 1 month and 1 year later (-19 ± 20%, -9 ± 17%, and -5 ± 14%, respectively; p = .27).

CONCLUSIONS: The morphological assessment of DCS with OCT revealed a high degree of strut coverage and apposition at 4 weeks after implantation. The impaired endothelium-dependent vasomotor response tended to improve chronologically from baseline to 1 month and 1 year later.