Implementation of the Obturator Nerve Block into a Supra-Inguinal Fascia Iliaca Compartment Block Based Analgesia Protocol for Hip Arthroscopy: Retrospective Pre-Post Study.
Аннотация
Background and
Objectives
The effect of supra-inguinal fascia iliaca compartment block (SI-FICB) in hip arthroscopy is not apparent. It is also controversial whether SI-FICB can block the obturator nerve, which may affect postoperative analgesia after hip arthroscopy. We compared analgesic effects before and after the implementation of obturator nerve block into SI-FICB for hip arthroscopy. Materials and
Methods
We retrospectively reviewed medical records of 90 consecutive patients who underwent hip arthroscopy from January 2017 to August 2019. Since August 2018, the analgesic protocol was changed from SI-FICB to SI-FICB with obturator nerve block. According to the analgesic regimen, patients were categorized as group N (no blockade), group F (SI-FICB only), and group FO (SI-FICB with obturator nerve block). Primary outcome was the cumulative opioid consumption at 24 hours after surgery. Additionally, cumulative opioid consumption at 6 and 12 hours after surgery, pain score, additional analgesic requests, intraoperative opioid consumption and hemodynamic stability, and postoperative nausea and vomiting were assessed.
Results
Among 87 patients, there were 47 patients in group N, 21 in group F, and 19 in group FO. The cumulative opioid (fentanyl) consumption at 24 hours after surgery was significantly lower in the group FO compared with the group N (N: 678.5 (444.0-890.0) µg; FO: 482.8 (305.8-635.0) µg; p = 0.014), whereas the group F did not show a significant difference (F: 636.0 (426.8-803.0) µg).
Conclusion
Our findings suggest that implementing obturator nerve block into SI-FICB can reduce postoperative opioid consumption in hip arthroscopy.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.