MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.medengphy.2019.09.020

Медицинская библиотека · Medical engineering & physics · 2019

A workflow for patient-specific fluid-structure interaction analysis of the mitral valve: A proof of concept on a mitral regurgitation case.

Biffi Benedetta, Gritti Maurizio, Grasso Agata, Milano Elena G, Fontana Marianna, Alkareef Hamad, Davar Joseph, Jeetley Paramijit, Whelan Carol, Anderson Sarah, Lorusso Donatella, Sauvage Emilie, Maria Bosi Giorgia, Schievano Silvia, Capelli Claudio

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The mechanics of the mitral valve (MV) are the result of the interaction of different anatomical structures complexly arranged within the left heart (LH), with the blood flow. MV structure abnormalities might cause valve regurgitation which in turn can lead to heart failure. Patient-specific computational models of the MV could provide a personalised understanding of MV mechanics, dysfunctions and possible interventions. In this study, we propose a semi-automatic pipeline for MV modelling based on the integration of state-of-the-art medical imaging, i.e. cardiac magnetic resonance (CMR) and 3D transoesophageal-echocardiogram (TOE) with fluid-structure interaction (FSI) simulations. An FSI model of a patient with MV regurgitation was implemented using the finite element (FE) method and smoothed particle hydrodynamics (SPH). Our study showed the feasibility of combining image information and computer simulations to reproduce patient-specific MV mechanics as seen on medical images, and the potential for efficient in-silico studies of MV disease, personalised treatments and device design.

Для цитирования: Biffi Benedetta, Gritti Maurizio, Grasso Agata, Milano Elena G, Fontana Marianna, Alkareef Hamad, Davar Joseph, Jeetley Paramijit, Whelan Carol, Anderson Sarah, Lorusso Donatella, Sauvage Emilie, Maria Bosi Giorgia, Schievano Silvia, Capelli Claudio. A workflow for patient-specific fluid-structure interaction analysis of the mitral valve: A proof of concept on a mitral regurgitation case.. Medical engineering & physics. 2019. DOI: 10.1016/j.medengphy.2019.09.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.