MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00134-005-2768-0

Медицинская библиотека · Intensive care medicine · 2005

Stroke output variations calculated by esophageal Doppler is a reliable predictor of fluid response.

Vallée Fabrice, Fourcade Olivier, De Soyres Olivier, Angles Olivier, Sanchez-Verlaan Pascale, Pillard Fabien, Smail Nadia, Olivier Michel, Genestal Michèle, Samii Kamran

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Esophageal Doppler allows continuous monitoring of stroke volume index (SVI) and corrected flow time (FTc). We hypothesized that variations in stroke output index SOI (SVI/FTc) during volume expansion can predict the hemodynamic response to subsequent fluid loading better than the static values.

DESIGN AND

SETTING

Prospective study in the intensive care unit of a university hospital.

PATIENTS: Fifty-one patients with circulatory failure were monitored by esophageal Doppler.

INTERVENTIONS: Patients who responded to a first fluid challenge received a second one. Patients who responded to both were classified as responders-responders, and those who did not respond to the second as responders-nonresponders. In these two groups we compared DeltaSVI, DeltaFTc, and DeltaSOI during each fluid challenge and also static values at the end of each fluid challenge.

MEASUREMENTS AND

RESULTS

After the first fluid challenge DeltaSOI and DeltaSVI were significantly higher in patients who responded to subsequent volume expansion than in patients who no longer responded. ROC curves showed that DeltaSOI was a better predictor of fluid responsiveness than DeltaSVI. During volume expansion a DeltaSOI value of 11% discriminated between responders and nonresponders to subsequent volume expansion with a sensitivity of 91% and a specificity of 97%. There was no significant difference between the two groups for FTc value at the end of first fluid challenge.

CONCLUSIONS

Analysis of DeltaSOI during fluid challenge predicts response to subsequent fluid challenge and FTc is not a reliable indicator of cardiac preload.

Для цитирования: Vallée Fabrice, Fourcade Olivier, De Soyres Olivier, Angles Olivier, Sanchez-Verlaan Pascale, Pillard Fabien, Smail Nadia, Olivier Michel, Genestal Michèle, Samii Kamran. Stroke output variations calculated by esophageal Doppler is a reliable predictor of fluid response.. Intensive care medicine. 2005. DOI: 10.1007/s00134-005-2768-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.