Could the two-minute step test be an alternative to the six-minute walk test for patients with systolic heart failure?
Аннотация
BACKGROUND
The consequence of exercise intolerance for patients with heart failure is the difficulty climbing stairs. The two-minute step test is a test that reflects the activity of climbing stairs.
DESIGN
The aim of the study design is to evaluate the applicability of the two-minute step test in an assessment of exercise tolerance in patients with heart failure and the association between the six-minute walk test and the two-minute step test.
METHODS
Participants in this study were 168 men with systolic heart failure (New York Heart Association (NYHA) class I-IV). In the study we used the two-minute step test, the six-minute walk test, the cardiopulmonary exercise test and isometric dynamometer armchair.
RESULTS
Patients who performed more steps during the two-minute step test covered a longer distance during the six-minute walk test (r = 0.45). The quadriceps strength was correlated with the two-minute step test and the six-minute walk test (r = 0.61 and r = 0.48). The greater number of steps performed during the two-minute step test was associated with higher values of peak oxygen consumption (r = 0.33), ventilatory response to exercise slope (r = -0.17) and longer time of exercise during the cardiopulmonary exercise test (r = 0.34). Fatigue and leg fatigue were greater after the two-minute step test than the six-minute walk test whereas dyspnoea and blood pressure responses were similar.
CONCLUSION
The two-minute step test is well tolerated by patients with heart failure and may thus be considered as an alternative for the six-minute walk test.