MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1073/pnas.0509009103

Медицинская библиотека · Proceedings of the National Academy of Sciences of the United States of America · 2006

Tissue biodistribution and blood clearance rates of intravenously administered carbon nanotube radiotracers.

Singh Ravi, Pantarotto Davide, Lacerda Lara, Pastorin Giorgia, Klumpp Cédric, Prato Maurizio, Bianco Alberto, Kostarelos Kostas

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Carbon nanotubes (CNT) are intensively being developed for biomedical applications including drug and gene delivery. Although all possible clinical applications will require compatibility of CNT with the biological milieu, their in vivo capabilities and limitations have not yet been explored. In this work, water-soluble, single-walled CNT (SWNT) have been functionalized with the chelating molecule diethylentriaminepentaacetic (DTPA) and labeled with indium ((111)In) for imaging purposes. Intravenous (i.v.) administration of these functionalized SWNT (f-SWNT) followed by radioactivity tracing using gamma scintigraphy indicated that f-SWNT are not retained in any of the reticuloendothelial system organs (liver or spleen) and are rapidly cleared from systemic blood circulation through the renal excretion route. The observed rapid blood clearance and half-life (3 h) of f-SWNT has major implications for all potential clinical uses of CNT. Moreover, urine excretion studies using both f-SWNT and functionalized multiwalled CNT followed by electron microscopy analysis of urine samples revealed that both types of nanotubes were excreted as intact nanotubes. This work describes the pharmacokinetic parameters of i.v. administered functionalized CNT relevant for various therapeutic and diagnostic applications.

Для цитирования: Singh Ravi, Pantarotto Davide, Lacerda Lara, Pastorin Giorgia, Klumpp Cédric, Prato Maurizio, Bianco Alberto, Kostarelos Kostas. Tissue biodistribution and blood clearance rates of intravenously administered carbon nanotube radiotracers.. Proceedings of the National Academy of Sciences of the United States of America. 2006. DOI: 10.1073/pnas.0509009103.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.