m+Medelevator.RU
← Поиск публикаций
BJOG : an international journal of obstetrics and gynaecology · 2014

Poor effectiveness of antenatal detection of fetal growth restriction and consequences for obstetric management and neonatal outcomes: a French national study.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Monier I, Blondel B, Ego A, Kaminiski M, Goffinet F, Zeitlin J

Аннотация

OBJECTIVE: To assess the proportion of small for gestational age (SGA) and normal birthweight infants suspected of fetal growth restriction (FGR) during pregnancy, and to investigate obstetric and neonatal outcomes by suspicion of FGR and SGA status at birth.

DESIGN: Population-based study.

SETTING: All French maternity units in 2010.

POPULATION: Representative sample of singleton births (n = 14,100).

METHODS: We compared SGA infants with a birthweight of less than the 10th percentile suspected of FGR, defined as mention of FGR in medical charts (true positives), non-SGA infants suspected of FGR (false positives), SGA infants without suspicion of FGR (false negatives) and non-SGA infants without suspicion of FGR (true negatives). Multivariable analyses were adjusted for maternal and neonatal characteristics hypothesised to affect closer surveillance for FGR and our outcomes.

MAIN OUTCOME MEASURES: Obstetric management (caesarean, provider-initiated preterm and early term delivery) and neonatal outcomes (late fetal death, preterm birth, Apgar score, resuscitation at birth).

RESULTS: 21.7% of SGA infants (n = 265) and 2.1% of non-SGA infants (n = 271) were suspected of FGR during pregnancy. Compared with true negatives, provider-initiated preterm deliveries were higher for true and false positives (adjusted risk ratio [aRR], 6.1 [95% CI, 3.8-9.8] and 4.6 [95% CI, 3.2-6.7]), but not for false negatives (aRR, 1.1 [95% CI, 0.6-1.9]). Neonatal outcomes were not better for SGA infants if FGR was suspected.

CONCLUSION: Antenatal suspicion of FGR among SGA infants was low and one-half of infants suspected of FGR were not SGA. The increased risk of provider-initiated delivery observed in non-SGA infants suspected of FGR raises concerns about the iatrogenic consequences of screening.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты