Trueness and Precision Achieved With Conventional and Digital Implant Impressions: A Comparative Investigation of Stone Versus 3-D Printed Master Casts.

Mathey A, Brägger U, Joda T

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To analyze implant casts obtained from intraoral optical scanning and conventional impressions.

MATERIALS AND

METHODS

Ten optical scans (test) and ten conventional polyether impressions (control) were obtained from a two-implant reference model. Ten casts each were manufactured additively or from stone. All casts were digitized and virtually superimposed to the digital reference (trueness) applying a best-fit algorithm, and secondary analysis for intra-group comparisons (precision). The signed nearest neighbor distance of each surface point (FDI:24/26) was computed and deviations of the three-dimensional vectors (X,Y,Z) analyzed. The groups were compared with the Wilcoxon's rank sum test.

RESULTS

The printed casts had mean deviations of 106.0μm and the stone casts 187.9μm compared to the reference. Controls had significantly higher deviations and dispersion (p⟨0.001). The printed casts showed mean intra-group deviations of 149.8μm and the stone casts 181.2μm without significant differences (p=0.162). There was no statistically significant difference in any of the vector analyses (X:p=0.105, Y:p=0.089, Z:p=0.123).

CONCLUSION

Optical scanning seems to be an alternative to conventional impressions in terms of trueness and precision of implant master casts, simulating the scenario of a three-unit implant-supported fixed dental prosthesis. Digitally manufactured master casts might serve as reliable reference for the final restorations.

Для цитирования: Mathey A, Brägger U, Joda T. Trueness and Precision Achieved With Conventional and Digital Implant Impressions: A Comparative Investigation of Stone Versus 3-D Printed Master Casts.. The European journal of prosthodontics and restorative dentistry. 2021. DOI: 10.1922/ejprd_2114mathey08.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.