MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0186710

Медицинская библиотека · PloS one · 2017

Laboratory evaluation of immunochromatographic rapid diagnostic tests for cholera in Haiti.

Matias Wilfredo R, Julceus Fabrice E, Abelard Cademil, Mayo-Smith Leslie M, Franke Molly F, Harris Jason B, Ivers Louise C

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Rapid diagnostic tests (RDT) for cholera are promising tools for detecting cholera in areas with limited laboratory infrastructure. However, evidence on the characteristics of the many available RDTs is scarce, and their use has been limited by suboptimal performance. We evaluated the performance characteristics of three cholera RDTs from Span Diagnostics, Artron Laboratories, and Standard Diagnostics in a regional laboratory in Haiti.

METHODOLOGY/PRINCIPAL FINDINGS: We retrospectively reviewed records from May 2014 to October 2015 of a laboratory-based surveillance program for Vibrio cholerae at Hôpital Saint-Nicolas in Saint-Marc, Haiti. We compared the results of 511 Crystal VC, 129 Artron and 451 SD Bioline RDTs to bacterial culture as the gold standard. Of 905 cultures, 477 (52.7%) were positive for V. cholerae O1, of which 27.7% were serotype Inaba. No cultures grew V. cholerae O139. Sensitivity and specificity of Crystal VC were 98.6% (95%CI: 96.5%-99.6%) and 71.1% (95%CI: 64.7%-76.9%), respectively. Artron demonstrated a sensitivity of 98.6% (95%CI: 92.7%-100%) and specificity of 69.1% (95%CI: 55.2%-80.9%). SD Bioline demonstrated a sensitivity of 81.1% (95%CI: 75.6%-85.8%) and specificity of 92.8% (95%CI: 88.4%-95.9%). Crystal VC and Artron frequently showed false positive O139 bands, whereas none were seen with SD Bioline.

CONCLUSIONS/SIGNIFICANCE: There is significant variation in the performance of different cholera diagnostic RDTs. Artron and Crystal VC RDTs have high sensitivity and low specificity, while SD Bioline RDT has low to moderate sensitivity and high specificity when performed by laboratory technicians in Haiti. Study limitations included its retrospective design. The suboptimal characteristics of these tests limit their use as clinical point-of-care tests; however, they may be useful in outbreak response, surveillance, and research in resource-limited settings.

Для цитирования: Matias Wilfredo R, Julceus Fabrice E, Abelard Cademil, Mayo-Smith Leslie M, Franke Molly F, Harris Jason B, Ivers Louise C. Laboratory evaluation of immunochromatographic rapid diagnostic tests for cholera in Haiti.. PloS one. 2017. DOI: 10.1371/journal.pone.0186710.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.