MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/acer.70126

Медицинская библиотека · Alcohol, clinical & experimental research · 2025

High-throughput quantitation of acetaldehyde and ethanol in mice using gas chromatography/mass spectrometry positive chemical ionization.

Lin Yu-Hong, Chen Cheng, Wei Shoupeng, Adrien Guillot, Mackowiak Bryan, Pan Hongna, Fu Yaojie, Maccioni Luca, Ren Tianyi, Zhang Li, Hibbeln Joseph, Pawlosky Robert, Gao Bin

СтатьяПоддержка NIH: внешняя программаResearch Support, N.I.H., IntramuralПеревод в очереди

Аннотация

BACKGROUND

Acetaldehyde, an immediate ethanol metabolite, mediates many ethanol-induced behavioral effects and is both psychoactive and toxic to animals and humans. Monitoring the kinetics of acetaldehyde using rodent models of alcohol misuse is essential for understanding and managing ethanol-associated diseases. However, quantitation of acetaldehyde in biological specimens after alcohol consumption has been challenging due to its high volatility, relatively low concentrations, and strong reactivity toward biochemical molecules. It was necessary to develop and establish an accurate and high-throughput method to quantitate acetaldehyde and ethanol.

METHODS

Gas chromatography/mass spectrometry in positive chemical ionization mode coupled with a 111-vial headspace autosampler was employed to quantitate acetaldehyde and ethanol using 2H4-acetaldehyde and 2H5-ethanol as internal standards. A multidimensional approach was used to develop the method, including sample collection and processing, instrumental data analysis, optimization, and validation. Blood and tissues collected from genetically modified mouse models and their wild-type counterparts were studied.

RESULTS

The method was validated and applied to quantitate acetaldehyde and ethanol in blood and tissues from multiple mouse studies on ethanol metabolism. Acetaldehyde and ethanol were well-resolved from chromatographic interferences with linear ranges of 6.25-800 μM for acetaldehyde and 1.25-160 mM for ethanol. Both regression coefficients for calibration curves were >0.999. The within- and between-run precisions for ethanol in plasma, whole blood, and serum were all <5.0%, and for acetaldehyde in plasma and serum were <9.0%, while in whole blood it was 19.2%. Sample throughput was on the order of 60 samples per 15 h daily, with a maximum of 111 per batch.

CONCLUSIONS

Despite some limitations, this validated method proved to be specific, accurate, and reproducible for high-throughput quantitation of acetaldehyde and ethanol in rodent plasma, whole blood, serum, and visceral organs.

Для цитирования: Lin Yu-Hong, Chen Cheng, Wei Shoupeng, Adrien Guillot, Mackowiak Bryan, Pan Hongna, Fu Yaojie, Maccioni Luca, Ren Tianyi, Zhang Li, Hibbeln Joseph, Pawlosky Robert, Gao Bin. High-throughput quantitation of acetaldehyde and ethanol in mice using gas chromatography/mass spectrometry positive chemical ionization.. Alcohol, clinical & experimental research. 2025. DOI: 10.1111/acer.70126.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.